Inventorying And Monitoring Storage Devices; Monitoring Storage Devices Using Web Interface - Dell iDRAC 8 User Manual

Table of Contents

Advertisement

Feature Name
PERC 9 Controllers
H830 H730
Reset controller
Real-
configuration
time
Create or change
Real-
security keys
time
Inventory and
Not
remotely monitor the
applic
health of PCIe SSD
able
devices
Prepare the PCIe
Not
SSD to be removed
applic
able
Securely erase the
Not
data
applic
able
Configure Backplane
Real-
mode
time
Blink or unblink
Real-
component LEDs
time
Switch controller
Stage
mode
d

Inventorying and monitoring storage devices

You can remotely monitor the health and view the inventory of the following Comprehensive Embedded Management (CEM)
enabled storage devices in the managed system using iDRAC web interface:
RAID controllers, non-RAID controllers, and PCIe extenders
Enclosures that include Enclosure Management Modules (EMMs), power supply, fan probe, and temperature probe
Physical disks
Virtual disks
Batteries
However, RACADM and WS-MAN display information for most of the storage devices in the system.
The recent storage events and topology of storage devices are also displayed.
Alerts and SNMP traps are generated for storage events. The events are logged in the Lifecycle Log.
NOTE: If you enumerate the enclosure view's WSMAN command on a system while one PSU-cable is removed, the
primary status of the enclosure view is reported as Healthy instead of Warning.

Monitoring storage devices using web interface

To view the storage device information using Web interface:
194
H730
H330
P
Real-
Real-
Real-
time
time
time
Real-
Real-
Real-
time
time
time
Not
Not
Not
applic
applica
applica
able
ble
ble
Not
Not
Not
applic
applica
applica
able
ble
ble
Not
Not
Not
applic
applica
applica
able
ble
ble
Real-
Real-
Real-
time
time
time
Real-
Real-
Real-
time
time
time
Stage
Staged
Staged
d
PERC 8 Controllers
FD33x
FD33x
H810
S
D
Real-
Real-
Staged
time
time
Real-
Real-
Staged
time
time
Not
Not
Not
applica
applica
applicabl
ble
ble
e
Not
Not
Not
applica
applica
applicabl
ble
ble
e
Not
Not
Not
applica
applica
applicabl
ble
ble
e
Real-
Real-
Not
time
time
applicabl
e
Real-
Real-
Real-
time
time
time
Staged
Staged
Not
applicabl
e
H710P
H710
H310
Staged
Staged
Staged
Staged
Staged
Staged
Not
Not
Not
applicable
applicabl
applicab
e
le
Not
Not
Not
applicable
applicabl
applicab
e
le
Not
Not
Not
applicable
applicabl
applicab
e
le
Not
Not
Not
applicable
applicabl
applicab
e
le
Real-time Real-
Real-
time
time
Not
Not
Not
applicable
applicabl
applicab
e
le
PCIe
SSD
Not
applicabl
e
Not
applicabl
e
Real-
time
Real-
time
Staged
Not
applicabl
e
Real-
time
Not
applicabl
e

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idrac 7

Table of Contents