Power factor is the ratio of real power consumed to the apparent power. When power factor correction is enabled, the server
consumes a small amount of power when the host is OFF. By default, power factor correction is enabled when the server is shipped
from the factory.

Configuring power supply options using web interface

To configure the power supply options:
1.
In iDRAC Web interface, go to Overview → Server → Power/Thermal → Power Configuration → Power Configuration. The
Power Configuration page is displayed.
2.
Under Power Supply Options, select the required options. For more information, see iDRAC Online Help.
3.
Click Apply. The power supply options are configured.

Configuring power supply options using RACADM

To configure the power supply options, use the following objects with the set command:
System.Power.RedundancyPolicy
System.Power.Hotspare.Enable
System.Power.Hotspare.PrimaryPSU
System.Power.PFC.Enable
For more information, see the iDRAC RACADM Command Line Interface Reference Guide available at dell.com/idracmanuals.

Configuring power supply options using iDRAC settings utility

To configure the power supply options:
1.
In iDRAC Settings utility, go to Power Configuration.
NOTE: The Power Configuration link is available only if the server power supply unit supports power monitoring.
The iDRAC Settings Power Configuration page is displayed.
2.
Under Power Supply Options:
Enable or disable power supply redundancy.
Enable or disable hot spare.
Set the primary power supply unit.
Enable or disable power factor correction. For more information about the options, see the iDRAC Settings Utility Online
Help.
3.
Click Back, click Finish, and then click Yes.
The power supply options are configured.

Enabling or disabling power button

To enable or disable the power button on the managed system:
1.
In iDRAC Settings utility, go to Front Panel Security.
The iDRAC Settings Front Panel Security page is displayed.
2.
Select Enabled to enable the power button or Disabled to disable it.
3.
Click Back, click Finish, and then click Yes.
The settings are saved.