Enabling Or Disabling Remote Racadm; Enabling Or Disabling Remote Racadm Using Web Interface; Enabling Or Disabling Remote Racadm Using Racadm; Disabling Local Racadm - Dell iDRAC 8 User Manual

Table of Contents

Advertisement

Enabling or disabling remote RACADM

You can enable or disable remote RACADM using the iDRAC Web interface or RACADM. You can run up to five remote RACADM
sessions in parallel.
NOTE: Remote RACADM is enabled by default.

Enabling or disabling remote RACADM using web interface

1.
In iDRAC Web interface, go to Overview → iDRAC Settings → Network → Services.
2.
Under Remote RACADM, select the desired option and click Apply.
The remote RACADM is enabled or disabled based on the selection.

Enabling or disabling remote RACADM using RACADM

NOTE: It is recommended to run these commands on the local system.
To disable remote RACADM:
racadm set iDRAC.Racadm.Enable 0
To enable remote RACADM:
racadm set iDRAC.Racadm.Enable 1

Disabling local RACADM

The local RACADM is enabled by default. To disable, see

Enabling IPMI on managed system

On a managed system, use the Dell Open Manage Server Administrator to enable or disable IPMI. For more information, see the Dell
Open Manage Server Administrator's User Guide at dell.com/support/manuals.
NOTE: From iDRAC v2.30.30.30 or later, IPMI supports IPv6 address protocol for Linux-based operating systems.

Configuring Linux for serial console during boot

The following steps are specific to the Linux GRand Unified Bootloader (GRUB). Similar changes are required if a different boot
loader is used.
NOTE: When you configure the client VT100 emulation window, set the window or application that is displaying the
redirected Virtual Console to 25 rows x 80 columns to make sure the correct text displays. Else, some text screens may
be garbled.
Edit the /etc/grub.conf file as follows:
1.
Locate the General Setting sections in the file and add the following:
serial --unit=1 --speed=57600 terminal --timeout=10 serial
2.
Append two options to the kernel line:
kernel ............. console=ttyS1,115200n8r console=tty1
3.
Disable GRUB's graphical interface and use the text-based interface. Else, the GRUB screen is not displayed in RAC Virtual
Console. To disable the graphical interface, comment-out the line starting with splashimage.
120