Locate the locking ever (1) attached to both fittings. Push in the lever until it
clicks. Attach the larger quick release coupling (3) (1/4 NPT threads) to your
compressed air supply line (4). Use Teflon tape on the threads to prevent
leaks. Push the quick release coupling (3) into the fitting (2) until it clicks into
place. Attach the other end of the supply line (4) to a particulate filter (5),
desiccant/dryer (6), and then to an oil-free compressed air source (7). If you
have purchased the optional Air Compressor, connect the control wire (8)
from the compressor (7) to the AUX IN connector (9). If using an inert gas,
attach the smaller quick release coupling (11) (1/4 NPT threads) to the
supply line (12) using thread sealant or Teflon tape. Push the quick release
coupling (11) into the fitting (10) until it clicks into place. Attach the other end
of the supply line (12) to an external pressure regulator (13) and then on to
the gas tank (14).
Cone Installation and Removal (both styles)
The cone must be attached to direct the air or gas
supply to the laser beam's focus point. To install the
cone, insert the cone (1) into the cone base completely
until it bottoms out. Using a .050 inch Allen wrench,
tighten the setscrew on the side of the cone base (2)
until it is snug. Re-check to make sure that the cone is
all the way into the base and is not tilted. To remove the
cone, simply loosen the setscrew (2) and pull the cone
straight down. DO NOT remove or loosen the cone base
mounting screws (3) & (4) to mount or dismount the
cone. These screws keep the cone base aligned with
the laser beam.
DO NOT install the cone unless you plan
on using Air Assist. Leaving the cone attached to the cone base and running the laser
system without either air or gas flowing through the cone will destroy the focus lens
within a few minutes. If you are not using Air Assist, REMOVE THE CONE. Damage
of this nature is due to neglect and WILL NOT be covered under warranty.
How it Works
Standard Air Assist
The Quick Release Fitting (1) is the entry point into the rear
enclosure of the laser system. From there, the air lines branch
off into two paths, the optics protection path and the cone path.
The optics protection path is a direct path from the quick
release fitting (1) to the beam window (5), the #2 mirror (6),
and the #3 mirror (7). Since this is a direct path, the amount of
air pressure and flow that is coming from your compressed air
source will be applied to the optics to help keep them clean
from flying debris. The cone path goes through the adjustment
valve (2), to the gauge (3), and then to the cone (4). The
amount of air, flowing through the cone, is adjusted using the adjustment valve (2) and monitoring the
pressure displayed on the gauge (3).
downward flow directly into the beam path at the focus point.
ACCESSORIES
The cone path protects the focus lens and provides a
Section 6-3