Superspeed-6
laser engraving and cutting systems00 (82 pages)
Summary of Contents for Universal Laser Systems M Series
Page 1
COMPRESSOR M, V, and X Class, M-300, V-400, X-600 and X2-600 Laser Systems Installation and Operation Instructions 02/2001...
Page 2
“ON” all of the time. This is useful for non-computer controlled Air Assisted systems such as the M Series Laser System or it can be used on the X Series if you wish. “OFF” is obviously off. The “AUTO”...
Page 3
Laser System Needle Valves Gauge AUXIN HIGH CONTROL WIRE FITTING LEVER DRYER FILTER SWITCH ON OFF AUTO BLUE COILED HOSE FUSES CONEXALL FITTING Maintenance The filter and desiccant should be inspected every 8 hours of use. It may be necessary to clean out the filter and change the desiccant that is inside the Dryer Assembly.
Page 4
Removal, Cleaning, and Replacement of the Filter 1. Turn Air Compressor “OFF” and unplug it. 2. Unscrew the cover by turning it 1/8 turn counterclockwise like you were unscrewing a jar, and pull down. The clear plastic container might still remain attached to the top. Gently pull this part straight down.
Page 5
7. Install metal cover and turn 1/8 turn until lever clicks into place. If you have any questions or concerns about how to use the Air Compressor or Air Assist options, please call, fax, or send email to: Universal Laser Systems Inc. Worldwide Service Center 16008 North 81...