Cylinder Battery Charging Diagram (With Black Stator) With Battery Isolator - Mercury 75 Service Manual

Table of Contents

Advertisement

3 Cylinder Battery Charging Diagram
(with BLACK STATOR) with Battery
Isolator
IMPORTANT: After electrical connections are
made, coat all terminal connections using Quick-
silver Liquid Neoprene (92-25711), to avoid cor-
rosion.
BLK = BLACK
BLU = BLUE
BRN = BROWN
GRY = GRAY
GRN = GREEN
PUR = PURPLE
RED = RED
TAN = TAN
VIO = VIOLET
WHT = WHITE
YEL = YELLOW
g
a - Stator
b - Terminal Block
c - To Tachometer
d - Voltage Regulator/Rectifier
e - Battery Isolator
f - Auxiliary Battery
90-830234R3 DECEMBER 1997
j
RED
RED
i
h
B1
RED
A
B2
e
f
a
b
GRY
c
k
RED
l
RED
g - Start Battery
h - To Remote Control Harness
i - 20 Ampere Fuse
j - Starter Solenoid
k - Small Red (Sense)Lead
l - Large Red (Output) Lead
d
GRY
YEL
YEL
51051
ELECTRICAL - 2B-11