Mercury 75 Service Manual page 71

Table of Contents

Advertisement

c. Test each CDM.
Stop Circuit Test
@ Cranking Speed
Positive Meter
Negative
Lead ( +)
Meter Lead (–)
Connect to
Connect to
Black/Yellow
Black Test
Test Harness
Harness Lead
Lead
If CDM Stop Circuit reading is below specifications,
replace that CDM.
90-830234R3 DECEMBER 1997
Test each CDM.
400 DVA Scale
DVA
Positive Meter
Reading
White Test
Harness Lead
100 - 300
If reading is below specifications replace trigger. If
reading is above specifications check CDM.
NOTE: If voltage remains low after installing a new
trigger, replaced CDM.
Trigger Output Test
@ Cranking Speed
Negative
Lead (+)
Meter Lead (–)
Black Test
Harness Lead
2 DVA Scale
DVA
Reading
0.2 - 5.0
ELECTRICAL - 2A-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

75 marathon75 sea pro11512565/80 jet90 ... Show all

Table of Contents