To shut down the pump:
1. Switch off the machine. Switch to „0" position.
2. Cut off the water supply.
3. Open the spray gun briefly until the pressure is released.
4. Apply the safety catch on the spray gun.
5. Remove the water hose and spray gun.
6. Pull the plug from the socket.
7. Winter: store the pump in rooms above 0°C.
8. Clean the water filter.
Frost protection
Normally after operation, there is still some water in the device. Thus, you must take
special measures to protect the device from frost.
- Completely drain the device
For this purpose, separate the device from the water supply. Then, turn on the
main switch and open the gun. Now, the pump presses the remaining water out of
the water tank and the pump. However, do not allow the device to operate without
water for longer than one minute.
- Fill the device with antifreeze agent
If the device is not operated for longer periods, especially over the winter, you
should pump an antifreeze agent through the device. For this purpose, fill the anti-
freeze agent into the water box and turn on the device. Wait with opened gun,
until the agent spurts out of the nozzle.
However, the best way to protect the device from frost is
10
To shut down the pump:
to store it at a frost-free location.