To shut down the pump

When using detergents

Put chemistry sieve number 5 into the deter-
gent container. Open the detergent valve (6),
then the detergent is sucked in. When closing
the detergent valve, the chemistry supply is
automatically closed. Allow detergent to act and
then wash off. (see page 5).
Note that you must always comply with the
instructions provided by the manufacturer
of the detergent (e.g. safety clothing) and the
water protection regulations!
5
Only open the valve, if the chemistry
sieve is in a liquid. Sucked in air leads
to the destruction of the pump seals !!!
Damages to the pump caused by sucked in
air are not covered by the guarantee.
6
To shut down the pump:
1. Switch off the machine. Device switch to „0" position.
2. Cut off the water supply.
3. Open the spray gun briefly until the pressure is released.
4. Apply the safety catch on the spray gun.
5. Remove the water hose and spray gun.
6. Pull the plug from the socket.
7. Winter: store the pump in rooms above 0°C.
8. Clean the water filter.
Frost protection
Normally after operation, there is still some water in the device. Thus, you must take
special measures to protect the device from frost.
- Completely drain the device
For this purpose, separate the device from the water supply. Then, turn on the main
switch and open the gun. Now, the pump presses the remaining water from the water
tank and the pump. However, do not allow the device to operate without water for lon-
ger than one minute.
- Fill the device with antifreeze agent
If the device is not operated for longer periods, especially over the winter, you should
pump an antifreeze agent through the device. For this purpose, fill the anti-freeze
agent into the water box and turn on the device. Wait with opened gun, until the agent
comes from the nozzle.
However, the best way to protect the device from frost is
to store it at a frost-free location.