Adjusting the pressure
This is accomplished by
turning the handwheel.
The default setting is
maximum pressure.

To shut down the pump:

1. Switch off the machine
2. Cut off the water supply
3. Open the spray gun briefly until the pressure is released
4. Apply the safety catch on the spray gun
5. Remove the water hose and high pressure hose
6. Drain the pump: switch on the motor for approx. 20 seconds
7. Winter: store the pump in rooms above 0° C
8. Clean the water filter
Preparation for use
4. The machine can be connected
to a pressurised water line with cold
or up to 70 °C hot water (see page 2).
Ensure that the water supply ist clean
when sucking from external sources.
The hose cross section must be
at least 1/2" = 12.7 mm (free
passage). Filter must
always be clean.
Please make sure that the filter is
clean before using your high pressure
cleaner.
5. Maximum induction
height 2.5 m - see tech-
nical data
on page 2.
Water