To Shut Down The Pump - Kranzle K 1050 TS T Original Operating Manual

Hide thumbs Also See for K 1050 TS T:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15

To shut down the pump

1. Switch off the high pressure cleaner
2. Cut off the water supply
3. Open the trigger gun with safety catch briefly until the
pressure is released
4. Apply safety catch on the trigger gun
5. Remove water hose and trigger gun with safety catch
6. Drain the pump: switch on the motor for approx. 10 seconds
7. Pull the plug from the socket
8. Clean HP hose and wind up without loops
9. Clean power cable and wind up
10. Clean water filter
11. Store high pressure cleaners in frost-free rooms in winter
44
Due to their small base, the compact and
mobile Kränzle machines are easy to store.
Small repairs - do it yourself!
Problem:
No water from nozzle although motor is running.
Cause:
Most likely the nozzle is blocked.
Pull plug from socket prior to starting any repair work!
No or very little water from the lance.
Proceeding:
Switch off the cleaner. Pull plug from
the socket. Operate trigger gun with
safety catch several times to decrease the
pressure.
Unscrew trigger gun and lance first,
then rinse high pressure gun to remove
possible soiling.
Check water inlet filter for soiling.
If the problem still exists, take wire (paper
clip) and push through nozzle opening.
If cleaning by means of a wire is not
successful, replace lance.