3.4Battery Type
①Sealed(Default)
④ User(Apply to PC software "Solar Station Monitor")
Battery Voltage Parameters (parameters is in 12V system at 25℃, please use double
value in 24V.)
Battery charging setting
Over Voltage Disconnect
Voltage
Charging Limit Voltage
Over Voltage Reconnect
Voltage
Equalize Charging Voltage
Boost Charging Voltage
Float Charging Voltage
Boost Reconnect Charging
Voltage
Low Voltage Reconnect
Voltage
Under Voltage Warning
Reconnect Voltage
Under Volt. Warning Volt.
Low Volt. Disconnect Volt.
Discharging Limit Voltage
Equalize Duration (min.)
Boost Duration (min.)
NOTE:
1) When the battery type is sealed, gel, flooded, the adjusting range of equalize
duration is 0 to180min and boost duration is 10 to180min.
2)The following rules must be observed when modifying the parameters value in
user battery type(factory default value is the same as sealed type):
a. Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging
Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect
Charging Voltage.
b. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
c. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥
Discharging Limit Voltage.
d. Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥
Discharging Limit Voltage.
e. Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.
②Gel
③Flooded
Sealed
16.0V
15.0V
15.0V
14.6V
14.4V
13.8V
13.2V
12.6V
12.2V
12.0V
11.1V
10.6V
120
120
Gel
16.0V
15.0V
15.0V
——
14.2V
13.8V
13.2V
12.6V
12.2V
12.0V
11.1V
10.6V
——
120
16
Flooded
User
16.0V
9~17V
15.0V
9~17V
15.0V
9~17V
14.8V
9~17V
14.6V
9~17V
13.8V
9~17V
13.2V
9~17V
12.6V
9~17V
12.2V
9~17V
12.0V
9~17V
11.1V
9~17V
10.6V
9~17V
120
0~180
120
10~180