3Operation

3.1LED Indictor Instruction

LED Indicator

3.2 Dry Contact Working Mode

1)Manual Mode
When the dry contact working mode is manual mode, it can control the ON/OFF of
external equipment through the dry contact switch button or remote button.
Example 1:
It shall connect controller‟s dry contact in parallel to the inverter start switch, so it can
turn ON/OFF the inverter by operating the button. As shown below:
Color
Indicator
Green
On Solid
Green
Slowly Flashing
Green
OFF
Green
On Solid
Green
Slowly Flashing
Green
Fast Flashing
Orange
On Solid
Red
On Solid
Red
Flashing
Status
PV connection normal but low
voltage(irradiance) from PV,
no charging
In charging
No PV voltage(night time) or
PV connection problem
Normal
Full
Over voltage
Under voltage
Over discharge
Battery Overheating