Alternator

To remove and to fit
Operation 14-2
To remove
Note: To assist with the assembly operation, identify and mark the positions of all wiring before it is
disconnected.
1 Disconnect the batteries before any service work is attempted.
2 Remove the access panel in the fan guard.
3 Loosen the alternator pivot bolt (A3), the adjustment link bolt which is behind the fan pulley and the
adjustment bolt (A4). Move the alternator to release the drive belt and remove the drive belt from the alternator
pulley.
4 Disconnect the wiring loom from the alternator.
5 Remove the bolts (A3 and A4) and remove the alternator.
To fit
1 Fit the alternator and retain with the pivot bolt (A3) and the adjustment link bolt (A4). Do not tighten the bolts
at this stage.
2 Fit the alternator drive belt over the alternator pulley and set the tension as given in Operation 14-3.
3 Connect the wiring loom to the alternator.
4 Fit the access panel to the fan guard.
5 Connect the batteries.