Connect Drain Line; Install Electric Power Lines - Cleveland steamcraft 21-CET-8 Service Manual

Counter type convection steamer
Hide thumbs Also See for steamcraft 21-CET-8:
Table of Contents

Advertisement

Page 16
Model 21 -CET-8 Service Manual

Connect Drain Line

Install Electric Power Lines

Connect the drain to the steamer as described below.
1. The SteamCraft 3.1 is supplied with a 1-1/4-inch pipe connection at the
rear of the unit (Figure 2-14).
2. When assembling the pipes and fittings of the drain outlet extension, apply
a hardening type pipe sealant to the threads, and thread them together
FINGER TIGHT ONLY. DO NOT USE A WRENCH.
Furnishing and installing the electrical power lines, switches, fuse boxes,
connectors and accessories is the responsibility of the owner and/or installer.
Figure 2-15 illustrates an electrical layout recommended by Cleveland Range.
When installing the electrical power lines and accessories, observe the
following instructions.
1. In the United States, install the electrical power lines in accordance with
local codes and/or the National Electric Code, ANSI/NFPA No. 70-1990
(USA).
2. In Canada, install the electrical power lines in accordance with local codes
and/or the Canadian Electrical Code, CSA Standard C22.1 (Canada).
3. Install the proper size disconnect switch, circuit breaker or fuses, and wire
and conduit to conform to all local codes and the national codes cited
above. See Table 2-3 for wire requirements.
4. Install a separate disconnect switch and fuses or breakers sized to meet the
line amps required by the SteamCraft 3.1 (see Table 2-3). The fuses or
breakers may be an integral part of the disconnect switch or in a separate
fuse box. Install the disconnect switch for easy access asneeded for daily
start up and shutdown. Throughout the remainder of this manual the fused
disconnect switch is referred to as the main power switch.