Printed 12/90
a. When installing a water supply system without a SteamerGard,
Cleveland Range recommends the plumbing layout illustrated in
Figure 2-18. This is a single water line from the main cold water supply
to the tee just outside the SteamCraft 3.1. The two separate lines from
the tee to the steam generator and condenser/blowdown connections
are comparitively short.
b. When installing a water supply system with a SteamerGard,
Cleveland Range recommends the plumbing layout illustrated in
Figure 2-19. Note the following details:
• This is a single water line from the main cold water supply to the tee
just before the SteamerGard. The two separate lines from the tee
to the SteamerGard intake connection and the SteamCraft 3.1
condenser/blowdown connection are comparatively short.
• The water supply to the condenser connection can be untreated.
• The treated water supply connects to the steam generator fill
connection.