Dryer Element (7, Figure 6-8); Fuses (8, Figure 6-7); On/Off Switch (10, Figure 6-5) - Cleveland steamcraft 21-CET-8 Service Manual

Counter type convection steamer
Hide thumbs Also See for steamcraft 21-CET-8:
Table of Contents

Advertisement

Dryer Element
(7, Figure 6-8)
Fuses
(8, Figure 6-7)
ON/OFF Switch
(10, Figure 6-5)
The heater coils, connected in a delta configuration, provide 8-kW heating power.
Each heater coil supplies one third of this power (2.67 kW). Table 5-1 lists electrical
characteristics of elements supplied for various voltages.
Table 5-1. Steam Generator Heater Elements
PART NO.
WATTS
103881
8000
1038811
8000
1038815
8000
1038812
8000
1038814
8000
The 300-W dryer element mounts inside the generator near the top. The dryer
element eliminates any droplet carryover as the steam exits the generator.
Carryover of small water droplets results in improper cooking and soggy food.
Optimum steam convection cooking demands dry steam w ith no carryover.
Carryover also erodes and enlarges the nozzle holes.
Table 5-2. Steam Generator Dryer Elements
PART NO.
WATTS
104306
300
1043061
300
1043062
300
Some early SteamCraft 3.1 models use 500-watt dryer elements. When needed, use
300-watt elements listed in Table 5-2 as replacements.
Fuses are located in line between the terminal block and the main transformer.
These fuses protect the steamer from damage in case of an overcurrent in the
primary of the transformer. Overcurrent conditions may occur from a short in any of
the 120 VAC components or wiring in the steamer. Moisture from leaky plumbing or
hosedown of the steamer may be the cause. Fuses used in the SteamCraft 3.1
must be rated at 2 amps.
Power from the main transformer connects to the center terminals of the
double-pole/double-throw ON/OFF switch. In the ON position, as shown i
, the switch connects the center terminals to the bottom terminals,
Figure 5-4
as viewed from the terminal side (rear) of the switch.
Model 21-CET-8 Service Manual
VOLTS
OHMS/COIL +/-5%
208
16
240
22
380
54
415
65
480
86
VOLTS
OHMS +/-5%
208
144
240
192
480
768
Page 71
n
Printed 12/90

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents