Model-21 CET-8 Service Manual
This troubleshooting guide includes a list of symptoms
that may be encountered during routine operation and
maintenance. The first column on the left (problem)
describes these symptoms. The second column lists
possible causes for the problem listed in column one.
The third column lists remedies and or references for
the problems and causes in columns one and two. The
causes and remedies are listed in the order they should
be
PROBLEM
Switch light does not turn on when
POWER switch is pressed on.
POWER switch light on and steamer
does not make any steam in MANUAL
or TIMED mode.
Abnormal amount of steam coming
from drain.
Steam and/or water draining around
compartment door.
Steam flow does not stop when
TIMER stops.
OPERATOR'S TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
Power turned off at main power
switch.
Water supply to steamer shut off.
Water line strainer is clogged.
Inoperative controls or solenoid.
Hot water instead of cold water
connected to condenser fitting.
Water supply to condenser turned
off.
Condenser water line strainer is
clogged.
Water supply line to the condenser
blocked, broken, or leaking.
Inoperative condenser solenoid.
Inoperative controls.
Drain clogged or covered.
Door gasket or door parts worn.
Steamer not level.
Operating in manual mode.
Inoperative controls inside cabinet
checked, with the least costly and easiest to repair listed
first. The third column also refers to notes that are
grouped at the end of the troubleshooting guide. Refer to
these notes when instructed to do so. Do not try to correct
a problem that requires an authorized service
representative as this may adversely affect warranty
coverage.
REMEDY/REFERENCE
Turn on power at main power switch.
Open water supply valves.
Clean water supply strainer.
See note #1
Make proper connections.
Open water supply valve.
Clean out condenser water supply strainer.
Repair or replace water supply line.
note #1.
Replace solenoid
Turn off electricity at main power switch.
See note #1
Clean drain with USDA approved drain
cleaner.
See note #1
See note #2
Switch to timed mode for timer to be
effective.
Turn off electricity at main power switch.
See note #1
.
See page 20
. See note #1
.
.
.
.
.
Printed 12/90
.