Cleveland steamcraft 21-CET-8 Service Manual page 13

Counter type convection steamer
Hide thumbs Also See for steamcraft 21-CET-8:
Table of Contents

Advertisement

1. The Product Identification Plate located on the
back panel specifies the electric power
requirements.
2. For each unit, the installer must provide a ground
connection and a separate fused disconnect
switch.
3. Catastrophic damage will result from shifting the
SteamCraft 3.1 more than 10° out of level while
power is turned on at the unit's main power
switch.
4. The unit must have a cold water supply, NOT
HOT. The water supply must meet the quality
requirements of Table 2-2. and the pressure
requirements on page 18
5. A SteamerGard system is recommended when
water quality does not meet the Table 2-2
requirements.
INSTALLATION DIAGRAM NOTES
Figure 2-1. Schematic Installation Diagram
Model 21-CET-8 Service Manual
6. A manual shut off valve must be installed
between the main water supply and the steamer
supply lines. Refer to figures 2-18 and 2-19 for
the recommended component arrangements.
7. Run a single water line between the main cold
water supply and the tee. The separate steam
generator and condenser/blowdown supply fines
are comparatively short.
& The drain line must have a gravity flow away from
the steamer, and must not be connected to the
drain lines of any other equipment
9. The drain line must be free air vented. If the line
empties into a floor drain, there must be a one
inch minimum clearance between the drain line
and the floor drain openings.
Page 5