Thermography System VarioCAM
9. Introduction
Fig. 170 Button function settings
It is possible to assign one function to several buttons at the same time.
9.4.6
Menu item "Alarm"
The "Alarm" menu item can be used in order to define conditions, the fulfillment of which will trigger the
camera to perform actions.
Fig. 172 "Alarm" (Alarm) menu item
The activated alarm function is displayed in the toolbar below the logo with the symbol
in the setting menu 'Alarm Definition' is also shown in red. These displays are made irrespective of
whether an alarm condition is met or not. For two measurement objects (1. ROI and 2. ROI) temperature
thresholds can be defined, that apply to the average ("Avg"), temperature maximum ("Max") or
temperature minimum ("Min") of the corresponding measurement object or the overall picture ("Global").
For each ROI and the corresponding temperature threshold, a comparison is defined: > or <, where for
"max" only > and "Min" only < selectable is.
If these defined conditions are met, the following actions can be performed:
■
OSD
Alarm indication on display viewfinder including display of achieved condition
■
IRB
Image storage according to setting storage format
■
COM
Alarm signaling via RS232 interface *
■
Audio
Acoustic alarm signal output
■
DO1
Alarm signal at the digital output 1*
■
DO2
Alarm signal at the digital output 2*
■
AO1
Alarm signal at the analogue output 1*
■
AO2
Alarm signal at the analogue output 2*
User Manual
®
HD
Fig. 171 Button assignment – factory settings
Fig. 173 Alarm definition settings