(6&

Using Direct Numeric Entry Method

1. Access the indirect selector or reference parameter whose association you
want to change (for this example, drive Parameter 545 - [Spd Ref A Sel] as
shown below).
6WRSSHG
 +]
3RUW  'HY 3DUDP 
Spd Ref A Sel
3
3
3RUW
3RZHU)OH[ 
(6&
2. With any field (port, parameter, or bit) selected, press the # soft key to
display the Direct Numeric Entry pop-up box.
6WRSSHG
 +]
(GLW 6SG 5HI $ 6HO
  
(6&
3. Use the numeric keys to enter a number string that represents the target
parameter's device port number, parameter number and, only when the
target parameter is a bit parameter, its bit number.
The number string format is PPpppp.bb, where:
PP = device port number
pppp = target parameter number
bb = bit number (only used when target parameter is a bit parameter)
4. Press the ENTER soft key to enter the number string and complete the
parameter association.
The indirect selector or reference parameter screen re-appears with the
associated parameter information.