Main Screens; Status Screen - Allen-Bradley PowerFlex 20-HIM-A6 User Manual

Human interface module
Hide thumbs Also See for PowerFlex 20-HIM-A6:
Table of Contents

Advertisement

Chapter 3
HIM Components
Soft Key Label
0267
3$5
3*'1
3*83
5()
5(6(7
7(;7
723
833(5
9,(:
=21(6

Main Screens

26
Name
Function
Most
Restores most Host or Port device parameters to factory defaults.
Parameter Number
Navigates directly to a parameter.
Page Down
Scrolls down to the next page of data lines on the Device Version information screen.
Page Up
Scrolls up to the previous page of data lines on the Device Version information screen.
Reference
Enters the speed reference for the Host Drive.
Reset
Resets the Process screen's displayed monitoring items to the factory default monitoring items listed on
Text
Edits user-definable text for the device selected.
Top
• Displays the top (most recent) fault, alarm or event in a queue.
• Scrolls to the top line of data on the Device Version information screen.
Upper
Displays the upper 16 bits (bits 16...31) of a 32-bit Bit-type parameter.
View
• Toggles between select screens and views.
• Displays the time stamp screen from a fault, alarm or event queue screen.
Zones
Displays the Select Time Zone screen.
The HIM main screens include the Status screen, Process screen, Control screen,
Folder screens, and Fault Display screens, which are described in their respective
subsections that follow.

Status Screen

On power up, the Status screen
type of host drive, the Status screen displays the following information.
Displayed Information
Selected device icon and port number
(1)
Device name
Rating text (volts, amps)
Drive catalog text
Firmware version and hardware series
(1) The displayed default device name is dependent on the host drive. The device name can be
changed, for example, to Host Drive as shown in the screens below. See
Drive/Peripheral Name on page 35
(2) The firmware version and hardware series for a PowerFlex 750-Series drive can be shown using
HIM menu screens. For details, see
Figure 4 - Example Status Screens
6WRSSHG
 +]
Host Drive
240V
20G...D014
00
(6&
For PowerFlex 750-Series Drive
Rockwell Automation Publication 20HIM-UM001D-EN-P - February 2013
(Figure
750-Series
for details.
Checking Drive and Peripheral Firmware Revisions on page
$872
)
4.2A
00
5()
3$5
7(;7
(6&
For PowerFlex 7-Class Drive
4) is shown by default. Depending on the
Host PowerFlex Drive
7-Class
not applicable
(2)
Creating a User-Defined
47.
6WRSSHG
$872
 +]
)
Host Drive
240V
4.2A
Rev 3.002 Ser. A
5()
3$5
7(;7
page
36.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerflex 20-him-c6s

Table of Contents