About Memories Usable with FZ Series

The following types of memory can be used with FZ.
On-board memory
This is the area where images are temporarily stored when logging images using the logging function.
This uses ring memory and if the maximum number of save images has been reached, images are
overwritten starting with the oldest. This is cleared when the power is turned OFF.
RAMDisk
Image logging file, data logging file, and capture images can be saved.
As this is memory inside the FZ4, files can be saved and read faster than using USB memory.
However, capacity is a fixed 40 MB (256 MB for FZ4-11
/H11
) . Files saved in RAMDisk are
cleared when the power is turned OFF.
Application memory
This is a memory used for all applications.
8
This is a memory area that is used temporarily by applications. By confirming available memory, this
provides a rough standard for confirming status while operating. The user has no access to it.
Data memory (FZ4-6
/H6
, FZ4-7
/H7
only)
This is an area for holding current settings details of scene group data.
If this capacity is exceeded, adding units and copying scenes cannot be performed in edit flow.
Available data memory can be confirmed from the system menu.
Reference:
Checking System Information [System Information] (p.358)