Enter a delimiter at the end of commands.
In this manual, delimiters are expressed with "
Separate parameters with spaces. (Not required before delimiters.)
In the following cases, an error occurs. The system quits abnormally and the return values are returned
when an error occurs.
When non-existing commands are specified
The number of parameters is incorrect
The range of the parameters is incorrect
The content of parameters is incorrect
When action cannot be ended correctly with an action instruction command
Important
Commands can be input and measurement results can be output only when the Main screen is at the front and
the BUSY signal is OFF. When using only the serial commands (normal), the command execution completion
(BUSY OFF) can be recognized with the Fxxx method. Cannot receive commands when setting windows or the
Edit Flow windows are displayed (excluding Serial - Confirmation). On the Main screen, even if the screen is
switched to the Edit Flow window, etc., the data output after measurement will not be interrupted before all data
is output. Can not react to commands when windows other than the Main screen are displayed.

Command List (Non-procedure)

This section explains the input format for each command used in the serial normal method.
Commands are input with ASCII code.Both lowercase and uppercase letters can be used.
FZ4-11
/FZ4-H11
The configuration is as follows: USBDisk:E, USBDisk2:F, USBDisk3:G, and USBDisk4:H.
Execute command
Command
Abbreviation
BRUNCHSTART BSU
CLRMEAS
OFF
CPYSCENE CSD
DATASAVE
OFF
DELSCENE
DSD
ECHO
EEC
IMAGEFIT
EIF
IMAGESCROLL EIS
IMAGEZOOM EIZ
MEASURE
M
MEASUREUNIT MTU
MOVSCENE MSD
REGIMAGE
RID
RESET
OFF
TIMER
TMR
FZ4 User's Manual
".
Branches to the flow head (processing unit No. 0)
Clears all of the measurement values of the current scenes
Copies scene data
Saves System + Scene group data in the controller's memory
Deletes scene data
Returns an arbitrary string as it is to the external device, which has
sent the string
Returns the display position and display zoom ratio to their initial
values
Moves the image display position in parallel the specified distance
Zooms in/out the image display by the specified zoom ratio
Perform measurement once
Start continuous measurement
Complete continuous measurement
Executes measurement tests on specified units
Moves scene data
Registers specified image data as registered image
Loads the specified registered data as a measurement image
Restart the controller
Executes the specified command string after a specified delay
Controlling/Outputting through Serial Communication (Non-procedure)
Function
7
References
Reference: Detai l s (p.448)
Reference: Detai l s (p.449)
Reference: Detai l s (p.449)
Reference: Detai l s (p.453)
Reference: Detai l s (p.456)
Reference: Detai l s (p.460)
Reference: Detai l s (p.466)
Reference: Detai l s (p.471)
Reference: Detai l s (p.477)
Reference: Detai l s (p.487)
Reference: Detai l s (p.487)
Reference: Detai l s (p.488)
Reference: Detai l s (p.489)
Reference: Detai l s (p.489)
Reference: Detai l s (p.498)
Reference: Detai l s (p.500)
Reference: Detai l s (p.512)