Interchanging Servers; Performing An Integrity Check On The Active Server - Avaya S8700-Series Installing And Configuring

Hide thumbs Also See for S8700-Series:
Table of Contents

Advertisement

Chapter 4: Server configuration

Interchanging servers

To interchange the servers to check capability of the standby server to become the active
server:
1. Under Server, click Interchange Servers.
2. Verify the settings in the following fields:
Standby Busied: no
l
Standby Refreshed: yes
l
Standby Shadowing: on
l
Duplication Link: up
l
Control Network health: X/X/X for both servers, where X is the number of
l
administered IPSI port networks. For more information, see
translations
3. Click Interchange.
The system displays a confirmation message that the interchange has taken place.
This server is now the active server.
To perform another interchange so that the originally active server returns to being the active
server:
1. Access the server that is now the standby server. See.
2. Repeat the three steps for

Performing an integrity check on the active server

To perform an integrity check on the active server:
1. Log on to the System Management Interface and click Administration > Server
(Maintenance) > Status Summary.
2. Verify the following:
Mode: Active
Server Hardware: okay
Processes: okay
3. Select Server > Process Status.
4. Under Frequency, click Display Once.
5. Click View.
54 Installing and Configuring the Avaya S8500-Series Server
on page 57.
Interchanging
servers.
Chapter 5: IP interface

Advertisement

Table of Contents
loading