Section 5. Level 3 Programming; Additional Advanced Product Settings - Henny Penny LVG-102 Technical Manual

Split vat & full vat open fryers – gas
Table of Contents

Advertisement

5-1. ADDITIONAL ADVANCED
PRODUCT SETTINGS
June 2008

SECTION 5. LEVEL 3 PROGRAMMING

Used to access the following:
• TECH RESETS-Reset Recovery Faults/Passwords to
defaults
• SPCL PROG-Program filter control parameters and other
items
• CLOCK SET-Set the time-of-day clock / calendar
• DATA COMM-Data Communications, LonWorks, MMC,
etc.
• HEAT CTRL-Program heat algorithm control parameters
• TECH MODE-Control of outputs, display & button tests, etc.
• STATS MODE-Review, reset operating stats, diagnostic logs,
etc
1. Press and hold
shows in the display, followed by ENTER CODE.
2. Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first 2 product buttons), and
"A. TECH" & "RESETS" show in the displays.
>Tech Resets<
3. Press right √ button and "RECOVERY FAULTS" shows in
left display. Right display shows "CLR" and the number of
recovery error recorded. Press √ button to reset the number
to "0".
4. Press
shows in left display. Press √ button to reset all passwords
set in the controls.
• Use
• Press X button when finished with the current item, to
return to the main menu.
• Press X button a second time to exit Level 3
programming.
5-1
and
buttons until LEVEL - 3
button and "ALL PASSWORDS RESET"
button to go back to previous menu items.