4-5. FILTER AFTER

4-6. FILTER TIME

June 2008
The number of cook cycles between filtering the oil can easily
be programmed for all products.
1. Press and hold
shows in the display, followed by ENTER CODE.
2. Enter code 1, 2, 3, 4 (first 4 product buttons). "PROD"
and "COMP" show in the displays.
3. Press
button 4 times and "FILR AFTR" shows in the
left display.
4. Use the product buttons
number to cook cycles between filtering procedures from 0
to 99.
The length of time the fryer remains idle between cook cycles
before the controls suggest filtering.
1. Press and hold
shows in the display, followed by ENTER CODE.
2. Enter code 1, 2, 3, 4 (first 4 product buttons). "PROD"
and "COMP" show in the displays.
3. Press
button 5 times and "FILR TIME" shows in the
left display.
4. Use the product buttons
time between cook cycles from 0 to 18:00 hours.
For example, if "5:00" is programmed in the right display,
if the vat was not used for 5 hours after a cook cycle, the
controls would display "FILR NOW?" "YES NO".