i.8 Parameter Table
No.
Name
E2-01
Motor Rated Current
Multi-Function Digital
H1-01 to
Input Terminal S1 to
H1-08
S8 Function Selection
Multi-Function
H2-01
Contact Output
(terminal M1-M2)
Multi-Function
H2-02
Contact Output 2
(terminal M3-M4)
Terminal M5-M6
H2-03
function selection
(relay)
Power Consumption
H2-06
Output Unit Selection
MEMOBUS Register 1
H2-07
Address Select
MEMOBUS Register 1
H2-08
Bit Select
MEMOBUS Register 2
H2-09
Address Select
MEMOBUS Register 2
H2-10
Bit Select
Terminal A1 Signal
H3-01
Level Selection
Terminal A1 Function
H3-02
Selection
Terminal A1 Gain
H3-03
Setting
Terminal A1 Bias
H3-04
Setting
Terminal A3 Signal
H3-05
Level Selection
Terminal A3 Function
H3-06
Selection
Terminal A3 Gain
H3-07
Setting
Terminal A3 Bias
H3-08
Setting
Terminal A2 Signal
H3-09
Level Selection
Terminal A2 Function
H3-10
Selection
Terminal A2 Gain
H3-11
Setting
Terminal A2 Bias
H3-12
Setting
96
Description
Sets the motor nameplate full load current
in amps. Automatically set during
Auto-Tuning.
Selects the function of terminals S1 to S8.
Sets the function for the relay output
M1-M2.
Sets the function for the relay output
M3-M4.
Sets the function for the relay output
M5-M6
<1>
0: 0.1 kWh units
1: 1 kWh units
2: 10 kWh units
3: 100 kWh units
4: 1000 kWh units
Sets the addresses of the MEMOBUS/
Modbus registers from which data will be
sent to contact outputs 62 and 162.
Sets the bits for the MEMOBUS/Modbus
registers from which data will be sent to
contact outputs 62 and 162.
Sets the addresses of the MEMOBUS/
Modbus registers from which data will be
sent to contact outputs 63 and 163.
Sets the bits for the MEMOBUS/Modbus
registers from which data will be sent to
contact outputs 63 and 163.
0: 0 to 10 V
1: -10 to 10 V
Sets the function of terminal A1.
Sets the level of the input value selected in
H3-02 when 10 V is input at terminal A1.
Sets the level of the input value selected in
H3-02 when 0 V is input at terminal A1.
0: 0 to 10 V
1: -10 to 10 V
Sets the function of terminal A3.
Sets the level of the input value selected in
H3-06 when 10 V is input at terminal A3.
Sets the level of the input value selected in
H3-06 when 0 V is input at terminal A3.
0: 0 to 10 V
1: -10 to 10 V
2: 4 to 20 mA
3: 0 to 20 mA
Note:
Use DIP switch S1 to set
input terminal A2 for a
current or a voltage input
signal.
Sets the function of terminal A2.
Sets the level of the input value selected in
H3-10 when 10 V (20 mA) is input at
terminal A2.
Sets the level of the input value selected in
H3-10 when 0 V (0 or 4 mA) is input at
terminal A2.
No.
Name
Analog Input Filter
H3-13
Time Constant
Analog Input Terminal
H3-14
Enable Selection
H3-16
Terminal A1 Offset
H3-17
Terminal A2 Offset
H3-18
Terminal A3 Offset
Multi-Function Analog
H4-01
Output Terminal FM
Monitor Selection
Multi-Function Analog
H4-02
Output Terminal FM
Gain
Multi-Function Analog
H4-03
Output Terminal FM
Bias
Multi-Function Analog
H4-04
Output Terminal AM
Monitor Selection
Multi-Function Analog
H4-05
Output Terminal AM
Gain
Multi-Function Analog
H4-06
Output Terminal AM
Bias
Multi-Function Analog
H4-07
Output Terminal FM
Signal Level Selection
Multi-Function Analog
H4-08
Output Terminal AM
Signal Level Selection
H5-01
Drive Node Address
Communication Speed
H5-02
Selection
Communication Parity
H5-03
Selection
Stopping Method After
H5-04
Communication Error
(CE)
YASKAWA ELECTRIC TOEP C710636 04D U1000 Industrial MATRIX Drive Quick Start Guide
Description
Sets a primary delay filter time constant for
terminals A1, A2, and A3. Used for noise
filtering.
1: Terminal A1 only
2: Terminal A2 only
3: Terminals A1 and A2 only
4: Terminal A3 only
5: Terminals A1 and A3
6: Terminals A2 and A3
7: All terminals enabled
Adds an offset when the analog signal to
terminal A1 is at 0 V.
Adds an offset when the analog signal to
terminal A2 is at 0 V.
Adds an offset when the analog signal to
terminal A3 is at 0 V.
Selects the data to be output through multi-
function analog output terminal FM.
Set the desired monitor parameter to the
digits available in Uo-oo.
For example, enter "103" for U1-03.
Sets the signal level at terminal FM that is
equal to 100% of the selected monitor
value.
Sets the signal level at terminal FM that is
equal to 0% of the selected monitor value.
Selects the data to be output through multi-
function analog output terminal AM.
Set the desired monitor parameter to the
digits available in Uo-oo.
For example, enter "103" for U1-03.
Sets the signal level at terminal AM that is
equal to 100% of the selected monitor
value.
Sets the signal level at terminal AM that is
equal to 0% of the selected monitor value.
0: 0 to 10 V
1: -10 to 10 V
2: 4 to 20mA
0: 0 to 10 V
1: -10 to 10 V
2: 4 to 20 mA
Selects drive station node number (address)
for MEMOBUS/Modbus terminals R+, R-,
S+, S-. Cycle power for the setting to take
effect.
0: 1200 bps
1: 2400 bps
2: 4800 bps
3: 9600 bps
4: 19200 bps
5: 38400 bps
6: 57600 bps
7: 76800 bps
8: 115200 bps
Note:
Cycle power for the setting
to take effect.
0: No parity
1: Even parity
2: Odd parity
Note:
Cycle power for the setting
to take effect.
0: Ramp to stop
1: Coast to stop
2: Fast Stop
3: Alarm only