Chapter 1 Part Names - Mitsubishi Electric MELSEC iQ-F FX5 User Manual

Simple motion module
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

1
PART NAMES
This chapter describes the part names of the Simple Motion module.
2-4.5 Mounting hole
[3]
[2]
[1]
[12]
[13]
No.
Name
[1]
External input connection connector
[2]
Extension cable
Direct mounting hole: 2 holes of 4.5 (0.18") (mounting screw:
[3]
M4 screw)
[4]
Axis display LED (AX1, AX2, AX3, AX4)
[5]
POWER LED
[6]
RUN LED
[7]
ERROR LED
[8]
Extension connector
[9]
DIN rail mounting groove
[10]
Name plate
[11]
DIN rail mounting hook
[12]
Pullout tab
[13]
Power supply connector
[14]
SSCNET cable connector
[4]
[5]
[6]
[7]
[8]
[14]
Description
Connects to a mechanical system input, manual pulse generator/incremental
synchronous encoder, or forced stop input. (26-pin connector)
For the signal layout, refer to the following.
Page 19 Specifications of Interfaces with External Devices
Connects to a CPU module, etc.
Holes which are used when installed directly.
For details, refer to the following.
Page 16 LED Display Specifications
Connects to an expansion module on the next tier.
Using this slot, the module can be mounted to DIN rail "DIN46277" (width: 35 mm).
Serial No. etc., are printed.
Hook which is used for mounting the module onto the DIN rail.
Tab for removing from a CPU module, etc.
Connects to a module to the power.
Connects to a servo amplifier.
[9]