External input signal cable

The external input signal cable is not prepared as an option. Fabricate the cable on the customer side.
Connection diagram
Make the cable as shown in the following connection diagram.
■Differential-output type
Make the cable within 30 m (98.5 ft.).
Simple Motion module side
10126-3000PE (connector)
10326-52F0-008 (connector case)
HBL
18
HBH
17
HAL
5
HAH
4
HB
16
HA
3
EMI
10
EMI.COM
23
DI1
11
COM
13
DI3
12
DI2
24
COM
26
DI4
25
Shell
*1
FG
: Twisted pair cable
*1 Make sure to perform shield treatment on the used equipment side. Also, connect it to the shell of connector side.
Solderless terminal
HBL
HBH
Differential output type manual pulse
generator/INC synchronous encoder side
HAL
HAH
*1
FG
EMI
Forced stop input side
EMI.COM
DI1
DI3
External command/switching side
DI2
DI4
DICOM
FG
*1
Appendix 2 Connection with External Devices