■Interface between manual pulse generator/Incremental synchronous encoder (Voltage-output
type/open-collector type)
Input or
Signal name
Output
*1, *2
Input
Manual pulse generator,
phase A/PULSE
Manual pulse generator,
phase B/SIGN
Signal ground
*1 Set "1: Voltage-output/open-collector type" in "[Pr.89] Manual pulse generator/Incremental synchronous encoder input type selection" if
the manual pulse generator/Incremental synchronous encoder of voltage-output/open-collector type is used.
The default value is "1: Voltage-output/open-collector type".
*2 Set the signal input form in "[Pr.24] Manual pulse generator/Incremental synchronous encoder input selection".
Wiring example for manual pulse generator/incremental synchronous encoder
Wire the manual pulse generator/incremental synchronous encoder of differential output type and voltage output type/open-
collector type as follows.
Switch the input type of 40SSC-S by "[Pr.89] Manual pulse generator/Incremental synchronous encoder input type selection".
Use the external 5 V power supply (5 V DC±5%) for the power supply of the manual pulse generator/incremental synchronous
encoder.
In the case of voltage output type/open-collector type, connect the 0 V (-) of the manual pulse generator/incremental
synchronous encoder and the SG of 40SSC-S.
Select the external power supply with due consideration for the capacity of manual pulse generator/incremental synchronous
encoder.
Pin No.
Wiring example
HA
3
(A)
HB
16
(B)
SG
2
15
Internal circuit
A
Manual
pulse
generator/
Incremental
synchronous
encoder
B
Power
supply
5 V DC
+
-
5.2 External Input Connection Connector
5
5 WIRING
53