Bracket Mounting Procedure For St 700 Basic Transmitter; Figure 46 - St 700 Basic Transmitter - Angle Mounting Bracket Secured To A Horizontal Or Vertical; Table 30 - St 700 Basic Transmitter - Mounting Bracket Procedure - Honeywell ST 700 User Manual

Smartline pressure transmitters
Hide thumbs Also See for ST 700:
Table of Contents

Advertisement

12.5.2 Bracket Mounting Procedure for ST 700 Basic Transmitter,

If you are using an optional bracket, start with Step 1. For an existing bracket, start with Step 2.
5. Refer to Figure 46 for position of the bracket on a 2-inch (50.8mm) nominal, 2.38-inch
(60.4mm) actual, horizontal or vertical pipe, and install a "U" bolt around the pipe and
through the holes in the bracket. Secure the bracket with the nuts and lock washers provided.
Figure 46 – ST 700 Basic Transmitter - Angle Mounting Bracket Secured to a Horizontal or
6. Align the appropriate mounting holes in the Transmitter with the holes in the bracket. Use the
bolts and washers provided to secure the Transmitter to the bracket; see the following
variations.

Table 30 - ST 700 Basic Transmitter - Mounting Bracket procedure

Transmitter Type
DP with double-ended process heads
and/or remote seals
In-line GP and AP models (STG7xS
and STA7xS)
Dual-head GP and AP
Example: Inline model mounted to an optional angle bracket. See Figure
Page 80
Vertical Pipe
ST 700 SmartLine Pressure Transmitters User's Manual
Use Hardware
Alternate mounting holes in the ends of the
heads
The smaller "U" bolt provided to attach the
meter body to the bracket. See the
following example.
Mounting holes in the end of the process
head.
47.
Revision 8.0

Advertisement

Table of Contents
loading

Table of Contents