4.4.5 Mounting Transmitters with Small Absolute or Differential Pressure Spans

To minimize positional effects on calibration (zero shift), take the appropriate mounting
precautions for the respective Transmitter model.
mounting models STA722 and STA72L.
and front-to-back. Figure 9 shows how to level a Transmitter using a spirit level.
Figure 9 – ST 700 Standard Transmitter - Using a Spirit Balance to Level a Transmitter
Revision 8.0
You do this by leveling the Transmitter side-to-side
ST 700 SmartLine Pressure Transmitters User's Manual
Ensure that the Transmitter is vertical when