Honeywell HART STT700 Safety Manual
Honeywell HART STT700 Safety Manual

Honeywell HART STT700 Safety Manual

Smartline temperature transmitter
Hide thumbs Also See for HART STT700:

Advertisement

Quick Links

STT700 SmartLine Temperature
Transmitter
HART
®
Communications Options
Safety Manual
34-TT-25-20
Revision 1
June 2017
June 2017
STT700 Safety Manual
i

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell HART STT700

  • Page 1 STT700 SmartLine Temperature Transmitter HART ® Communications Options Safety Manual 34-TT-25-20 Revision 1 June 2017 June 2017 STT700 Safety Manual...
  • Page 2 In no event is Honeywell liable to anyone for any indirect, special, or consequential damages. The information and specifications in this document are subject to change without notice.
  • Page 3 STT700 SmartLine Temperature Transmitter HART/DE Option User’s Manual, # 34-TT-25-18 Patent Notice The Honeywell STT700 SmartLine Temperature Transmitter family is covered by one or more of the following U. S. Patents: 5,485,753; 5,811,690; 6,041,659; 6,055,633; 7,786,878; 8,073,098; and other patents pending.
  • Page 4 Support and Contact Information For Europe, Asia Pacific, North and South America contact details, refer to the back page of this manual or the appropriate Honeywell Solution Support web site: Honeywell Corporate www.honeywellprocess.com Honeywell Process Solutions www.honeywellprocess.com/temperature-transmitters/ Training Classes http://www.honeywellprocess.com/en-US/training...
  • Page 5 Terms and Abbreviations 1oo1 One out of one Basic Safety The equipment must be designed and manufactured such that it protects against risk of damage to persons by electrical shock and other hazards and against resulting fire and explosion. The protection must be effective under all conditions of the nominal operation and under single fault condition Dangerous Undetected failures...
  • Page 6: Table Of Contents

    Application limits ..........................3 4 — Installation with the HONEYWELL STT700 ............4 Parameter settings ..........................4 5 — Operation and Maintenance with the HONEYWELL STT700 ......5 Proof test ............................. 5 Calibration procedure .......................... 6 Remote Parameter Configuration Verification ..................7 Repair and replacement ........................
  • Page 7: Requirements

    1 — Requirements Requirements for use of the manual This section is intended for user’s who have our STT700 SmartLine Temperature Transmitter ® with the HART Communication option with SIL. Any other option is not specifically covered by this manual. IEC 61508 Ed.
  • Page 8: Safety Function

    2 — Safety Function Primary Safety Functions The HONEYWELL STT700 measures the temperature (or mV or ohms) of a process and reports the measurement within a safety accuracy of 2%. Secondary Safety Functions The HONEYWELL STT700 performs automatic diagnostics to detect internal failures and reports these failures via out-of-band signals on the 4 –...
  • Page 9: Designing With The Honeywell Stt700

    HONEYWELL. This report details all failure rates and failure modes, common cause factors for applications with redundant devices and the expected lifetime of the HONEYWELL STT700. The HONEYWELL STT700 is intended for low demand mode applications up to SIL 2 for use in a simplex (1oo1) configuration, depending on the PFD calculation of the entire Safety Instrumented Function.
  • Page 10: Installation With The Honeywell Stt700

    4 — Installation with the HONEYWELL STT700 The person with knowledge of safety operations will be required to do the installation and operation. No special installation is required in addition to the standard installation practices outlined in the STT700 Smart Transmitter User Manual. However please note that when the device is in safety operation that the optional write protect must be set in software so that the ®...
  • Page 11: Operation And Maintenance With The Honeywell Stt700

    HONEYWELL STT700 Proof test The objective of proof testing is to detect failures within the HONEYWELL STT700 that are not detected by the automatic diagnostics of the transmitter. Of main concern are undetected failures that prevent the safety instrumented function from performing its intended function.
  • Page 12: Calibration Procedure

    Calibration procedure The transmitter should be taken out of service. The source for the input Temperature must be very precise, and certified for correct operation. Step Action Connect the HART host and establish the communications. Go to Online > Device Setup > Advanced Configuration > Calibration > Calibration Methods menu. Go to “D/A trim”...
  • Page 13: Remote Parameter Configuration Verification

    Remote Parameter Configuration Verification When configuring the HONEYWELL STT700 through a remote host, it is recommended that parameters that affect the 4-20ma analog output be verified using an alternate utility, before using the transmitter in a SIS. This helps to ensure that the parameters that are entered remotely by the host are not inadvertently changed from the user intended values.
  • Page 14: Repair And Replacement

    Repair and replacement Any failures that are detected and that compromise functional safety should be reported to the Global Technical Support Center (GTS). When replacing the HONEYWELL STT700 the procedures in the installation manual should be followed. Firmware update The user will not be required to perform any firmware updates. If the user has selected the firmware upgrade option, it can be done by Honeywell service representative.
  • Page 15: Security

    Submit the requested information to Honeywell using one of the following methods: • Send an email to security@honeywell.com • Contact your local Honeywell Process Solutions Customer Contact Centre (CCC) or Honeywell Technical Assistance Centre (TAC) listed in the “Support and Contact information” section of this document.
  • Page 16 Phone: +(822) 799 6114 Fax: +(822) 792 9015 For more information To learn more about SmartLine transmitters, visit www.honeywellprocess.com Or contact your Honeywell Account Manager Process Solutions Honeywell 1250 W Sam Houston Pkwy S Houston, TX 77042 Honeywell Control Systems Ltd...