Trigger IN
Sensor Gate
(Normal Exposure
operation)
①
Exposure
Video Out used
for ALC control
③
ALC control
Signal
④
Video Output
8.7.2
RCT mode timing after the trigger is input
Primary settings to use this mode
Exposure Mode: Timed
Trigger Mode: ON
Trigger Option: RCT
Optical Filter Selector: 10µs
If ALC control is used together with RCT mode, then
Exposure auto: Continuous
Gain Auto: Continuous
Minimum interval of the trigger
Read out mode
Full
ROI 1/2 (Height=1024)
ROI 1/4 (Height=512)
1/2V Binning (Note 1)
(Note1) GO-5000M-USB only
GO-5000M-USB / GO-5000C-USB
②
Fig.25 RCT mode timing for ALC operation (Example)
Minimum trigger interval
16.447 ms
8.375 ms
4.35 ms
8.375 ms
- 43 -