Rct Mode; Rct Mode Together With Alc Function - IAI GO-5000M-USB User Manual

5m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

Trigger
CMOS
Exposure
Exposure
Active
FVAL
t1
10 μs (Min)
Note 1: The trigger is input through 6P optical input. Accordingly, the timing will be changed if
the optical filter is set to the other figures.
Note 2: Other timings are internal operating timing of the camera.
8.7.

RCT mode

8.7.1

RCT mode together with ALC function

RCT mode can use ALC control to ensure that the proper exposure is set when the trigger pulse is
input. In the following drawing, the steps to achieve this combination are explained.
① The exposure control is the same as in continuous mode.
② When the trigger signal is input, the charge that has already been accumulated during the
current exposure period is read out very quickly and a new exposure period starts. The
exposure continues as in continuous mode.
③ All video level data from every exposure is transferred to ALC control.
④ The video output sent to the GigE interface is only the signal after the trigger is input.
GO-5000M-USB / GO-5000C-USB
t1
t2
Exposure Period
t2
36 μs
Fig.24
Pulse width
- 42 -
t4
t3
t3
t4
32 μs
5L ~6L