Setting up the transmitter unit for a short or a long installation of an
antenna wire.
d-fence 6th SENSE - 2
transmitter unit power, which is generated into the antenna wire. This
function allows a fine setting of warning and correction zone for a short
installation (up to 400 m wire installation) and also for a long installation
(above 400 m wire installation). The newly purchased transmitter unit is
factory pre-set for the installation up to 400 m. When your installation is
longer, it is necessary to make the following settings.
Setting process:
Press MENU to enter the Main menu, by pressing
select Configuration, press ENTER to confirm your settings.
By pressing ENTER button choose Loop.
If your antenna wire installation is shorter than 400 m, select by pressing
buttons UP TO 400 m. If your antenna wire installation is
longer than 400 m, select OVER 400 m.
Use MENU button to return to the Main menu.
Important: In the Main menu – Zones settings – is the current setting
indicated by:
- installation up to 400 m
- installation over 400 m
Important: The loop of the transmitter unit needs to be calibrated after
each adjustment of the antenna wire installation length.
Calibration of the loop:
In the Main menu, select Measuring.
Disconnect the antenna connector with the installed loop (antenna
wire).
Press ENTER.
Check that you have disconnected the antenna connector from the
transmitter unit.
Press ENTER.
In the bottom line you will see a confirmation „Calibration successful!"