Bosch C 60 Manual page 140

Hide thumbs Also See for C 60:
Table of Contents

Advertisement

C 60 Recording and Telemetry
Configuration of Recordings
Recording Diagnosis
The channel 'stateclrl_ok' of the C 60 can be used for online monitoring of recording status
Bit
Value
Name
Content of status bits
Name
RECORD
DATAOK
BLKOK
STARTED
Motorsport
140
Internal | BEG/EMS1 CsM | 6/4/2010 | © Bosch Engineering GmbH 2009. All rights reserved, also regarding any disposal, exploitation,
reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
8
7
6
128
64
32
1
STARTED
1
Bit set
Measurement data is recorded
Received data without error
All measurement blocks have
been set up correctly
A measurement has been set up
5
4
3
16
8
4
1
1
BLKOK
Bit cleared
No measurement data will be
stored because measurement
thresholds are not reached
Discarding received data
because of wrong timestamps.
Check wiring of SYNC signal.
Some measurement blocks have
not been set up correctly.
A measurement is not set up.
Either no recording configuration
has been found or logger
software upgrade is not activated
2
1
2
1
DATAOK
RECORD

Advertisement

Table of Contents
loading

Table of Contents