C 60 Online Measurement
C 60 Online Measurement + Calibration
Online calibration of measurement channels
Analog sensors drift with age, temperature, etc.
Manual calibration is necessary
Solution: online offset calibration
Example: acceleration sensor
Acc
Sensor datasheet:
400mV/G
Offset 2500mV
Motorsport
117
Internal | BEG/EMS1 CsM | 6/4/2010 | © Bosch Engineering GmbH 2009. All rights reserved, also regarding any disposal, exploitation,
reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
Due to sensor drift:
at 0G physical
U
=2400mV
IN
sensor output
U
IN
Offset calibration
At 0G physical
Acc
0G measurement
U
IN