2 Power supply

Please ensure that you have a good ground installation. That means:
A ground that has a solid, low resistance connection to the negative battery terminal.
·
Connection should be free from dirt, grease, paint, anodizing, etc.
·
Use large diameter wire
·
More metal-to-metal contact is better!
·
The following notations for power signals are used:
term15 is a switched battery rail controlled by the IGN-switch
·
term30 is an unswitched battery positive rail (same as battery positive terminal)
·
term31 is an unswitched ground rail (same as battery negative terminal)
·
Be careful to observe current limits of wires and connector pins!

3 Onboard network concept

UBAT
Star connection
(term30)
Main
Switch
G
GND_Starpoint
As short as
possible
4
IGN-
Switch
positive terminal
Chassis
Engine_GND
KL15
KL30
µC
KL31
Star connection
dig. sensors
(e.g. wheelspeed)
LS_GND_1
LS_GND_2
SENSGND
Power supply
switched pos. terminal
Electric Loads
C 60
Bosch Motorsport
diagnosis connector
LS_SWITCH1...4
UBATT_FUSE
SENSPWR10
SENSPWR5
ANA_IN(xy)
NTC
ANA_IN(xx)
Sensor
PC
active
Sensor