14.
To Steer: Select "DRIVE" position with Off/Lift/
Drive Select Key Switch. If equipped, activate
and hold the Enable switch (by squeezing the
trigger towards the joystick or pressing the
control box side mounted push button), then
press the rocker switch on top of the Drive/Steer
Controller handle in the direction you wish to
steer.
15.
To Climb a Grade: Select "
the Torque Toggle Switch.
MACHINE MUST BE IN FULLY RETRACTED
POSITION
16.
To extend/retract a manual extension platform:
To extend the platform remove the retaining
locking pins and push/pull the extension platform
using the push bar until the desired extension is
reached. Reinsert the locking pins to prevent
accidental movement of the extension deck
during travel or transport.
17.
To extend/retract a hydraulic powered
extension platform: To extend the platform,
turn key to "LIFT" position with Off/Lift/Drive
Select Key Switch, activate the Enable Switch,
then push the extension/retraction toggle switch
to the " " position until desired extension is
reached. Release switch to stop. To retract the
platform, turn key to "LIFT" position with Off/
Lift/Drive Select Key Switch, activate the Enable
Switch, then push the extension/retraction toggle
switch to the " " (retract) position until desired
retraction is reached. Release switch to stop.
18.
To switch from LP GAS to gasoline: Move fuel
selector switch on engine control panel to the
"GASOLINE" position. To shut off fuel, move
switch to "OFF" position.
To switch from gasoline to LP GAS: With the
engine running, move switch to "OFF" position
and let engine run until gasoline is exhausted
from carburetor. When engine stops, move
switch to "LP GAS" position and restart engine.
Make sure LP GAS valve is ON when switching
from gasoline to LP GAS and valve is OFF when
switching from LP GAS to gasoline.
SJ-600 Series Engine Powered
" position with
Warning
June 2001

Shutdown Procedure

1.
Completely lower the platform.
2.
Turn key to "OFF" position and remove key from
Off/Lift/Drive Select Key Switch in control box.
3.
Push Emergency Stop Button(s) in.
4.
Turn Emergency Power Disconnect Switch to
"OFF" position. CE units - remove key then
push in Emergency Stop Button on the base
control box.