Troubleshooting Information; Section 4 - Troubleshooting Information - Skyjack SJ-7027 Operating, Maintenance And Parts Manual

Sj-600 series
Table of Contents

Advertisement

TROUBLESHOOTING INFORMATION

The following pages contain a Table of Troubleshooting information for locating and correcting most
service trouble which can develop. Careful inspection and accurate analysis of the systems listed in the
Table of Troubleshooting Information will localize the trouble more quickly than any other method. This
manual cannot cover all possible troubles and deficiencies that may occur. If a specific trouble is not listed,
isolate the major component in which the trouble occurs, isolate whether the problem is electrical or
hydraulic, and then isolate and correct the specific problem.
TROUBLESHOOTING INFORMATION
TROUBLE
ALL CONTROLS
INOPERATIVE
NO POWER TO
PLATFORM
(Machines Without
Base Control Box
Option)
NO POWER TO
PLATFORM
(Machines With Base
Control Box Option)
SJ-600 Series Engine Powered
toc
1
2
3
SECTION 4
ELECTRICAL SYSTEM
PROBABLE CAUSE
1. Battery disconnected or discharged.
2. Loose or dirty battery cables.
3. Open or defective main power
disconnect switch (S1).
4. Loose or broken wire #03 from main
power disconnect switch (S1) to
circuit breaker (CB1).
5. Tripped or defective circuit breaker
(CB1).
6. Loose or broken wire #05 from
breaker (CB1) to base terminal block
(TB-1).
7. Loose or broken wire #05 from base
terminal block (TB-1) to engine off/
on switch (S30).
8. Loose or broken wire #100 from
battery
(B1)
to
disconnect switch (S1).
1. Open or defective engine off/on
switch (S30).
2. Loose or broken wire #07 from
engine off/on switch (S30) to base
terminal block (TB1).
3. Loose or broken wire #07 from base
terminal block (TB-1) to emergency
stop switch (S4).
4. Open or defective emergency stop
switch (S4).
1. Open or defective engine off/on
switch (S30).
2. Loose or broken wire #07 from
engine off/on switch (S30) to base
terminal block (TB-1).
3. Loose or broken wire #07 from base
terminal block (TB-1) to emergency
stop switch (S6).
4. Loose or broken wire #07 from
emergency stop switch (S6) to
platform/base select switch (S10).
112715
June 2001
5
6
1. Reconnect battery. Recharge if
discharged.
2. Clean and tighten battery cables.
3. Close switch. Replace if defective.
4. Check continuity.
defective.
5. Reset breaker. Check for defective
wiring. Replace breaker if defective.
6. Check continuity.
defective.
7. Check continuity.
defective.
8. Check continuity.
main power
defective
1. Check switch. Replace if defective.
2. Check continuity.
defective.
3. Check continuity.
defective.
4. Check switch. Replace if defective.
1. Check switch. Replace if defective.
2. Check continuity.
defective.
3. Check continuity.
defective.
4. Check continuity.
defective.
REMEDY
Replace if
Replace if
Replace if
Replace if
Replace if
Replace if
Replace if
Replace if
Replace if
SECTION 4, Page 1
4

Hide quick links:

Advertisement

Table of Contents
loading