LASER (SE955)
The tables below list reader settings as well as symbology settings for the Laser (SE955)
scan engine.
READER SETTINGS TABLE
Laser Engine
Description
Decode Time-out
Set the maximum time for decoding to continue during a
scan attempt.
1~9 (second)
Redundancy Level
Level 1
Following barcodes must be successfully read twice before being decoded:
Barcode Types
Codabar
MSI
Industrial 25 (Discrete 25)
Interleaved 25
Level 2
All barcodes must be successfully read twice before being decoded.
Level 3
All barcodes except for the following barcodes must be successfully read
twice before being decoded. Following barcodes must be read three times:
Barcode Types "Excluded"
MSI
Industrial 25 (Discrete 25)
Interleaved 25
All barcodes must be successfully read three times before being
Level 4
decoded.
Scan Angle
Select the scan angle for Long Range Laser scan engine.
"narrow" for 35°
"wide" for 47°
Scan Mode
Continuous Mode
Non-stop scanning
To decode the same barcode repeatedly, move away the scan beam
and target it at the barcode for each scanning.
Appendix II
Default
Level 1
Code Length
All
4 characters or less
8 characters or less
8 characters or less
Code Length
4 characters or less
8 characters or less
8 characters or less
Wide
Laser mode
3 sec.