Electromagnetic Flowmeters
SITRANS F M TRANSMAG 2
Operating Instructions • 11/2009
SITRANS F

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SITRANS F M TRANSMAG 2

  • Page 1 Electromagnetic Flowmeters SITRANS F M TRANSMAG 2 Operating Instructions • 11/2009 SITRANS F...
  • Page 3 Introduction Safety notes Description SITRANS F Installing Flowmeters SITRANS F M TRANSMAG 2 Connecting Commissioning Operating Instructions Functions Service and Maintenance Troubleshooting Technical data Parameters Profibus Communication Appendix 11/2009 A5E00102775-07...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Step 2: Connecting signal cables ....................26 Step 3: Connecting terminal box and transmitter.................27 Commissioning ............................31 Operating Transmag 2 .........................31 Write protection ..........................34 Language and illumination ......................35 Operating examples........................35 Functions ..............................39 Menu structure ..........................39 SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 6 Output Data (from Master to Slave) .................... 96 Diagnostics..........................97 Locking operation........................99 Device Database File (GSD)..................... 100 Literature list..........................104 Appendix..............................107 Certificates ..........................107 Accessories and spare parts..................... 107 Index..............................109 SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 7: Introduction

    It is the responsibility of the customer that the instructions and directions provided in the manual are read, understood and followed by the relevant personnel before installing the device. Items supplied ● SITRANS F M Transmag 2 ● Wall mounting kit (remote only) ● Cable glands (remote only) ● Ferrite cores...
  • Page 8: Further Information

    Product information on the Internet The Operating Instructions are available on the CD-ROM shipped with the device, and on the Internet on the Siemens homepage, where further information on the range of SITRANS F flowmeters may also be found: Product information on the internet (http://www.siemens.com/flowdocumentation)
  • Page 9: Safety Notes

    The CE mark symbolizes the compliance of the device with the following guidelines: ● EMC guideline 89/336/EWG ● Low voltage guideline 73/23/EWG ● Pressure equipment directive (PED/DGRL) 93/23/EG The SITRANS F M magnetic-inductive measuring devices comply with protection class I. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 10 Safety notes 2.2 Laws and directives SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 11: Description

    Description Overview SITRANS F M Transmag 2 is a pulsed alternating field magnetic flowmeter where the magnetic field strength is much higher than conventional DC pulsed magnetic flowmeters. This makes it ideal for difficult applications as: ● High concentrated paper stock > 3 % ●...
  • Page 12: Features

    – Functions of digital output 2 (relay): alarm, forward or reverse flow signal, min. or max. limit for flow and counter SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 13: Bus Communication

    – Option: digital output 2 as digital input for resetting counter values or for interruption in measurement (PZR) BUS Communication SITRANS F M Transmag 2 is available with HART or PROFIBUS communication. ● The HART protocol is superimposed on the analog output (current output). This communication capability permits parameterization of the device using the HART communicator or a PC/laptop and SIMATIC PDM software in addition to local operation.
  • Page 14 Description 3.4 BUS Communication SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 15: Installing

    If the surface of the sensor or sensor tube can get hotter than 50 ºC in the application, fire protection and/or a warning sign must be provided. CAUTION Make sure the measuring device is protected from direct sunlight when installing it outdoors. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 16: Sensor Installation

    It is recommended to use protective rings (orifice protectors) to protect the inlet and outlet edges of the sensor against mechanical damage especially when used with abrasive media. Protective rings are available as accessories. Vertical/horizontal installation Figure 4-1 Horizontal / vertical installation SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 17 Do not install the sensor in pipe sections with a free pipe outlet which could run empty. When installing in a downpipe, make sure that the pipe is always filled 100% with the medium Figure 4-3 Installation in pipes without emptying SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 18 The sensor must be installed in a culvert in the case of an unfilled pipe or only a free level line (outlet). Figure 4-5 Installation in a constantly filled pipe SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 19 To avoid the formation of eddy currents in the sensor, the angle of reduction should not be greater than 8°. < 8° Figure 4-6 Example of reduction of a line cross section Note Reductions cause losses in pressure. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 20: Potential Equalization Of Sensor (Refence Potential)

    (e.g. by grounding rings). Grounding rings serve to establish the reference potential of the sensor in electrically isolated pipes. Figure 4-8 Reference potential in electrically isolated pipes by grounding rings Grounding rings are offered as accessories. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 21: Turning The Local Display

    5. Pull out the unit, turn it to the desired position and push it back in. 6. Screw the lid back on and mount the lid catch. ① Fastening hooks Figure 4-9 Unlocking the fastening hooks on the local display SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 22: Transmitter Installation (Remote Version)

    1. Fit the mounting plate on the transmitter using the mounting material provided 2. Mount transmitter with mounting plate on the wall. Figure 4-10 Standard mounting plate Note The standard mounting plate is only suitable for wall mounting. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 23: Pipe Or Wall Mounting With Assembly Bracket

    1. Fasten the asembly bracket to the back of the transmitter 2. Fasten the transmitter and assembly bracket to the wall Note The fastening brackets and nuts are not needed for wall mounting. Wall mounting with assembly bracket SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 24 Installing 4.4 Transmitter installation (remote version) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 25: Connecting

    Terminal box for power supply and signal lines ③ Potential equalization ④ Signal line ⑤ Power supply ⑥ Electrode line ⑦ Terminal box for magnetic current and electrode line Figure 5-1 Overview, Electrical connections SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 26 – Cable glands 1/2" NPT 5 to 9 mm ① Lid of terminal box ② Cable gland Figure 5-2 Example of lazing cables before connecting the lines See also Wiring devices with Profibus PA (Page 92) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 27: Step 1: Connecting Power Supply

    Analog output (active) 4 to 20 mA resp. PROFIBUS ⑤ Power supply: L/N for 100 to 230 V AC ⑥ Terminal for PE conductor Figure 5-3 Connection diagram for power supply and signal cables SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 28: Step 2: Connecting Signal Cables

    ● A load of at least 250 Ω must exist in the signal circuit (see also Technical data (Page 73)) for error free communication via the HART protocol. See also Wiring devices with Profibus PA (Page 92) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 29: Step 3: Connecting Terminal Box And Transmitter

    5.4 Step 3: Connecting terminal box and transmitter Step 3: Connecting terminal box and transmitter WARNING The SITRANS F M Transmag 2 transducer may only be connected to measuring sensor for alternating fields SITRANS F M 911/E . The magnetic circuit carries dangerous mains voltage.
  • Page 30 3. Tighten the lock nut on the threaded bushing until the cable is connected tightly (IP67) ① Electrode line ② Magnetic current line Figure 5-4 Signal transmission from the sensor to the transmitter SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 31 Preparing the cables Prepare the cable before connection as shown below. 10...12 5...10 75...80 ① Connector sleeve ② Braided screen Figure 5-6 Preparation of the electrode and magnetic field current cable SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 32 The electrode cable (including the SmartPLUG supply voltage) must also be shielded and should have a wire gauge of 7 x 0.5 mm , (e.g. LIYCY). SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 33: Commissioning

    ● via the local display ● via HART or Profibus ● with a PC/laptop and SIMATIC PDM software Note The following explains how to operate the device via the local display. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 34 Optical (infared) keypad ③ Infrared transmitter Figure 6-1 Local display of the SITRANS F M Transmag 2 Note Operation does not require opening of the device. This means that the high degree of protection of IP67 is guaranteed at all times.
  • Page 35 Operating via BUS communication The device is integrated into the system as shown below: 230 Ω up to 600 Ω HART- communicator laptop Coupling module RS-232-C Figure 6-2 System integration via HART SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 36: Write Protection

    You can also enter the code number in the "6.1 Enter Code" menu item. The programming is disabled again: SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 37: Language And Illumination

    The following display appears after completing the data input (8th operating step) 3.1. Flow Engr. Unit You return to the initial position by actuating the operating element three times. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 38 In the following example the pulse rate is changed from 1 pulse per liter to 200 pulses per liter. 1. Navigate the menu and select menu item 4.2.3 "Pulse rate". Digit.output1 Pulse rate Note See Operating Transmag 2 (Page 31) for information on how to navigate the menu. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 39 +2.00 lmp./Unit 1. Move the decimal point two places to the right by pressing the twice 4.2.3 Pulse rate +200.00 lmp./Unit 1. Terminate the input by pressing three times Digit.output1 Pulse rate SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 40 Commissioning 6.4 Operating examples SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 41: Functions

    ● Illumination, menu item 1.1.5 (display test) Multi display (menu item 1.2) Simultaneous display of two measuring variables Flow (menu item 1.3) Display of current flow Totalizer (menu item 1.4) Display of total flow SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 42: Function Group Diagnostics

    1 and 2 and the analog output if configured accordingly (selection of ‘Alarm’ function for the digital outputs or ‘Failure signal’ for the analog output) (see menu items 4.1.2, 4.2.1 and 4.3.1). SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 43 If the electrodes have no contact with the medium, the alarm signal "Tube empty" is triggered through the digital outputs. This alarm is also triggered in the case of an insulating coating on the electrodes. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 44 (exit the menu item). Digital output 1 must be configured for the "Alarm" function for simulation of the alarm signal (setting in the menu item "4.2.1 Function"). SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 45: Function Group Measuring Functions

    Measured values outside the sensor limits are displayed but are no longer within the specified range; "uncertain, nonspecific, low limited" or "uncertain, nonspecific, high limited" is then reported as a measured value status. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 46 The limit values (menu items 3.1.3.1 and 3.1.3.2) can have a hysteresis added to prevent "fluttering" of the switching output. ① Measured variable ② Limit alarm ③ Time ④ Hysteresis - limit max. ⑤ Hysteresis - limit min. Figure 7-1 Limit value message and hysteresis SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 47 In "forwards" parameterization, only signals in this direction are output or accumulated internally. Example 1: Hysteresis = 0% Example 2: Hysteresis = 0% SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 48 This function serves to eliminate temporary, application-related interference within a fixed time frame. Every measured value within a measuring pulse is compared with the previously determined value. If it is outside the tolerance band set under menu item 3.1.7.3 (the SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 49 (menu item 3.1.7.1) or "Error blanking" functions, although this will in turn reduce the measuring dynamics. ① Unattenuated measuring variable ② Time ③ Tolerance band ④ t = suppress time SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 50 ● Alarm limit, menu item 3.2.3 Here you can set all values from 0 to +108. You can assign reaching or exceeding this limit value as a signal to a digital output. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 51 ● Hysteresis, menu item 3.4.5 The limit values (menu items 3.4.3 and 3.4.4) can have a hysteresis added to prevent "fluttering" of the switching output. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 52: Function Group Device Outputs

    In the current range between 0 and 20 mA, the 3.6 mA failure signal or "Stop" is not recommended; in this case, the setting ’22 mA’ or ’24 mA’ must be selected. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 53 0 to URV is shown in a linear way on the set current range as for the inactive Split mode. 20mA ① Output current ② Split value ③ ④ Flow Figure 7-5 Split mode in domain 4 ... 20 mA SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 54 (e.g. totalizer forwards, totalizer reverse). Note The connected PROFIBUS master must be configured with a device database file (GSD) according to the set ID No. See also Device Database File (GSD) (Page 100) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 55 External supply max. DC 30 V Figure 7-6 Active and passive signals You can generate signals with positive and negative logic (positive and negative pulses). The figure below illustrates the setting options. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 56 When "Split value active" is selected, the output is active when the current level of the flow value is within the lower subdomain 0 to "Split value". In this case the output current is SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 57 Setting No alarm Alarm message Reverse flow Forward flow No limit signalling Limit signalling 1. Contact closes 2. Contact opens ① Electronic fuse ② External supply Figure 7-8 Digital output 2 SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 58 External supply 11 ... 24 V (max. 30 V) Figure 7-9 Circuit diagram of digital input ● Signal type, menu item 4.3.2 You can determine the signal type (high-active) with this. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 59: Function Group Identification

    The Hart communication transmits only capital letters. For texts with more than 16 characters, the marks in the first and last segment of the device display respectively indicate that there are other characters to the left and/or right of the displayed text. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 60: Function Group Service

    The programming can also be disabled by entering any number which does not match the actual customer code in this menu item. After input of ’3333’ the fixed personal code is briefly displayed (help function as reminder). SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 61 ● Zero flow correction, menu item 6.6.1 This menu item serves to adapt the local hydraulic conditions. The zero point has a speed value of -1 to +1 m/s added. This setting is undone by entering "0". SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 62 ’Act.Value El1’ and ’Act.Value El2’. The switching threshold of the immersion check should be set under menu item ’Threshold’ to about midway between these two values. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 63: Service And Maintenance

    ● The magnetic current fuse is located on the measurement board. The magnetic current fuse type used is: – F 5A/250 V, IEC 127, 5,2 x 20 mm CAUTION The fuses can only be replaced by fuses of the same type. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 64: Recalibration

    Magnetic current fuse Position of the fuses Recalibration Siemens Flow Instruments offers to recalibrate the sensor. The following calibrations are offered as standard: ● Standard matched pair calibration ● Customer specified matched pair calibration (up to 10 points) ● Accredited matched pair calibration...
  • Page 65: Technical Support

    Service and Maintenance 8.5 Technical support Technical support CAUTION Repair and service must be carried out by approved Siemens Flow Instruments personnel only. Note Siemens Flow Instrument defines sensors as non-repairable products. Technical Support If you have any technical questions about the device described in these Operating Instructions and do not find the right answers, you can contact Technical Support: ●...
  • Page 66: Return Procedures

    Shipments without a declaration of decontamination will be cleaned professionally at your expense before further proceeding. You can find the forms on the Internet and also on the CD delivered with the device. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 67: Troubleshooting

    If the measured values are too low, transmitter is defective. If the measured values are zero or with a wrong polarity, check cable leads. See also If the sensor or transmitter is defective, contact your local Siemens representative: Local contact person (http://www.automation.siemens.com/partner) SITRANS F M TRANSMAG 2...
  • Page 68: Application Problems

    Measuring deviations, Inlet and outlet lines insufficient Change installation (see Sensor installation measuring errors (Page 14)) Highly turbulent flow profile Change inlet line, use flow rectifier, reduce diameter of tube SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 69 More than two bus terminations exist (incl. Reduce to two bus terminations coupler and link) PROFIBUS interface defective Check device status (menu 2.1): if "COM module failure" is signaled, replace the complete electronics SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 70: Error Messages

    Reduce flow quantity or increase upper range "Measurement module value in menu 3.1.2 failure" Device status (menu 2.1) Measuring electronics defective Measurement with reduced accuracy still "Measurement module" possible; replace complete electronics SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 71: Application Information Guide

    Fill in this form and attach it to a Support request on: Service and support (http://www.siemens.com/automation/service&support) From: Siemens Flow Instruments A/S Company: A&D PI 3 E-mail: Fax: +45 7449 0066 Phone no.: Fax no.: SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 72 Menu 3.1.5.2 Hysteresis Menu 3.1.5.3 Low flow cut-off (1%) Menu 3.1.6 Time constant (3.00 sec.) Menu 3.1.7.1 Slurry mode (off) Menu 3.1.8 Pulse rate / unit Menu 4.2.3 Pulse width Menu 4.2.4 SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 73 CFR value (are sensor and transmitter data the same?) Menu 6.7.2 ZPH value (are sensor and transmitter data the same?) Menu 6.7.3 Excitation frequency (bipolar PP) Menu 6.7.4 Grounding sensor (correct?) See system information SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 74 Troubleshooting 9.4 Application information guide SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 75: Technical Data

    Configurable for positive or negative logic Active signal DC 24 V, ≦ 24 mA, Ri = 170 Ω Passive signal Open collector, max. DC 30 V, 200 mA Output configuration Pulse SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 76: Reference Conditions

    Reference conditions Medium process temperature +25 °C ± 5 °C (77 °F ± 9 °F) Ambient temperature +25 °C ± 5 °C (77 °F ± 9 °F) Warm-up time min. 30 min SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 77 4.4 kg (9.7 lb) Compact versions Transmitter fixed onto measuring tube Remote version Transmitter must be connected to the sensor using shielded cables Maximum line length 100 m; (328 ft) Housing Die-cast aluminum, painted SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 78: Dimensions

    Line fuse AC 100 to 230 V: T1.6A Magnetic current fuse F5A/250 V 10.2 Dimensions (2.76) (3.54) (3.54) Figure 10-1 SITRANS FM Transmag 2 transmitter (remote design) with standard mounting plate SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 79 135 (5.315) 169 (6.654) (7.244) (9.803) (10.79) Weight of PN 16 8.0 (17.6) 11.0 11.5 25.0 (18.7) Version in kg (MWP (24.3) (25.4) (55.1) (57.3) (61.7) 145 psi Version in lb) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 80 (11.73 (12.76) (15.51) (17.40) (19.37) (18.46) (21.10) (24.84) (29.37) Weight of PN 10 Version in kg (75.0) (83.86) (149.9) (176.4) (198.4) (242.5) (330.7) (463) (860) (MWP 145 psi Version in lb) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 81: Parameters

    Off: automatic switch on by pressing key, switch off after 10 min Menu 1.1.2 Multi-Display Simultaneous display of two measuring (actual • variables measured value Menu 1.1.3 • line 1) (actual measured value line 2) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 82 120 s • empty’ is reported under device status. 300 s • Device Test Self Test Check device status (duration approx. 60s) 2.4.2 Display Test Visual check of local display Simulation SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 83 • Failure signal • Parameters apply only to devices with 20 mA/Hart communication and digital output 2 (7ME5034-0xxxx) Parameters apply only to devices with 20 mA/Hart communication and digital input (7ME5034-2xxxx) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 84: Measuring Functions

    • kg/l, g/l, lb/in , lb/lmpgal Engr. Unit Engineering unit of the medium density +1000.00 kg/m 200 ... 5000 kg/m • Density Density value for calculation of mass flow 3.1.5 Direction SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 85 -108 ... +108 Total. rev. Totalizer reverse Cancel 1,2, 3.3.1 Set reverse Reset totalizer to zero and stop or start Cancel 1,2 • Reset+Stop, Totalize 3 • Reset+Start 1,2, • Totalize 3 • SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 86 0 ... 20 mA • (menu 3.1.2) is shown. For the setting 0 to 20 mA the failure signal (menu 4.1.2) must be set to 22 or 24 mA. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 87 +0.1 ms 0.1 ... 2000 ms 4.2.5 Fullsc. Freq Frequency output at full scale flow value 10000 Hz 2 ... 10000 Hz at digital output 1 (only effective for "Frequency" function) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 88 Text max. 32 characters specific) Manuf.Ident. 5.2.1 Product type Transmitter order number (7ME5034- xxxxx-xxA0) 5.2.2 Serial number Transmitter serial number (N1xxxx- 82xxxxx) 5.2.3 Software Rev. Software version in the transmitter (3.x.x) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 89 Device reset (without parameter changes) Cancel • Reset • Control Values 6.5.1 Volt. Um Control value for magnetic field current Volt. Uref Control value for reference voltage 6.5.2 Volt. Usig Electrode differential voltage SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 90 (affects all outputs, totalizers and display) 6.7.2 Calibration value for hydraulic reference point at 1m/s Calibration value for reference path 6.7.3 Calibration value for hydraulic zero point SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 91 Parameters apply only to devices with 20 mA/Hart communication and digital output 2 (7ME5034-0xxxx) Parameters apply only to devices with 20 mA/Hart communication and digital input (7ME5034-2xxxx) Parameters apply only to devices with 20 mA/Hart communication and digital input (7ME504x-2xxxx) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 92 Parameters SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 93: Profibus Communication

    ● Digital output 2 (relay output) Data transfer The SITRANS F M Transmag 2 has a PROFIBUS-PA connection compliant with IEC 1158 (synchronous transmission) which transfers data at a fixed speed of 31.25 kBit/s. The min. TSDR at startup is 11 bit times and can then be changed using the "Set_Prm" service. The bus address has the value 126 in the as-delivered state and can be changed either with the DP service "Set_Slave_Add"...
  • Page 94: Wiring Devices With Profibus Pa

    Lid over terminals for power supply may not be removed! Use only certified measuring instruments! The Profibus PA variant of the SITRANS F M Transmag 2 differs from the HART variant with the 4-20 mA output in the bus interface and the omission of the digital output 2. The basic functions of the device including the operation and display remain basically the same.
  • Page 95: Cyclic Data Traffic

    "Obj80C4.rtf" which will be provided on request. Acyclic operation takes place preferably with the SIMATIC PDM software package and a PC (compatible with the industrial standard) or programming device (see section 5.1). SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 96: Input Data (From Slave To Master)

    Table B- 2 Status byte format Byte 7 (MSB) 0 (LSB) Quality Substatus Limits These components may adopt the following values in SITRANS F M: SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 97 Formats of the limit bits Profile Designation Meaning O.K. Measured value within the limit values (normal state) low limited Measured value has dropped below the lower limit (alarm, warning or sensor limit) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 98: Output Data (From Master To Slave)

    The output data consist per totalizer (net, forwards and reverse) of one byte of which only the two LSBs respectively are evaluated. All other bits are not evaluated but should be set to SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 99: Diagnostics

    Diagnostic information Byte 2 (not supported) Byte 3 (reserved) Byte 4 (s. below) Note on additional diagnostic data The total length of the external diagnostic data is always 8 including the header. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 100 The EXTENSION_AVAILABLE bits indicates that other diagnostic information is available, basically details of the DIAGNOSIS message. This information is displayed locally. Additionally, the measured value-related messages are transmitted cyclically with the measured values in the status byte (Substatus). SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 101: Locking Operation

    This write protection can be deactivated by the local operation in the case of a permanent communication failure by entering the code "2457" (menu item 6.1) >0: The general write protection is switched off. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 102: Device Database File (Gsd)

    Note As an alternative to the device-specific GSD, standard GSD for magnetic-inductive flow transmitters described in profile 3.0 can also be used, but does not support the manufacturer-specific extensions. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 103 45.45_supp = 1 93.75_supp = 1 MaxTsdr_31.25 = 100 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 1000 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Auto_Baud_supp = 0 SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 104 Unit_Diag_Bit(39) = "Ident_Number violation" Unit_Diag_Bit(55) = "Extension Available" User_Prm_Data_Len = 0 ;=========== Description of modules =============================== ; Use always the module order specified in this file. ; Use exactly one identifier per module. SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 105 ;--------------------------------------------------------------------- Module = "Flow" 0x94 EndModule ;--------------------------------------------------------------------- ; Module 2 - Quantity net ;--------------------------------------------------------------------- Module = "Quantity net" 0x41, 0x84, 0x85 EndModule Module = "Resettable quantity net" 0xC1, 0x80, 0x84, 0x85 SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 106: Literature List

    /1/ PROFIBUS: Brief Technical Description /2/ PROFIBUS PA - Profiles for Process Control Devices General Requirements V 3.0 /3/ PROFIBUS PA - Profiles for Process Control Devices Data Sheet Transmitter V 3.0 SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 107 Various material, including technical descriptions, can be downloaded here: http://www.profibus.com/download.html (http://www.profibus.com/) GSD: Device database file LSB: Least significant Bit MSB: Most Significant Bit PDM: Process Device Manager PNO: PROFIBUS user organization PROFIBUS PA: Process Fieldbus for Process Automation SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 108 Profibus Communication B.9 Literature list SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 109: Appendix

    Accessories and spare parts In order to ensure that the ordering data you are using is not outdated, the latest ordering data is always available on the Internet: See also Catalog process instrumentation (http://www.siemens.com/processinstrumentation/catalogs) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 110 Appendix C.2 Accessories and spare parts SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 111: Index

    Digital input, 57 Measuring functions, 84 Digital output 1, 54 Service, 59, 89 Digital output 2, 55 Function Group Dimensions, 78 Display, 39 Direction Fuses Flow, 45 Change of, 63 Measurement, 45 SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 112 System integration, 34 Write protection, 101 Maintenance, 63 Profibus PA, 11 Manufacturer data, 59 Protection degree, 13 Measuring accuracy, 76 Protective rings, 14 Media Protective washers, 9 Abrasive, 14 Pulse rate, 36, 55 SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 113 Tag data, 31, 58 Technical data, 75 Temperature Ambient and medium, 13 Totalizer forwards, 48 Totalizer net, 49 Totalizer reverse, 49 Totalizers, 39 Troubleshooting, 67, 68 URV, (See Flow Upper Range Value) SITRANS F M TRANSMAG 2 Operating Instructions, 11/2009, A5E00102775-07...
  • Page 114 For more information www.siemens.com/flow A5E00102775-07 Siemens Flow Instruments A/S Subject to change without prior notice Nordborgvej 81 Order No.: A5E00102775-07 DK-6430 Nordborg Copyright Siemens AG 11.2009 All rights reserved www.siemens.com/processautomation...

Table of Contents