Functions
7.4 Function Group Measuring Functions
Effect of a noise signal filter (example)
Total. forwards (Menu item 3.2)
You have the following setting options in this menu:
● Set, menu item 3.2.1
● Unit, menu item 3.2.2
● Alarm limit, menu item 3.2.3
48
Flow in % with filter time constant
Time
In this menu you can reset the forwards totalizer to zero and restart if necessary.
If the totalizer overruns the optical display of the totalizer stops at "999999999" but the
device continues counting internally. You have to set a greater unit to be able to read the
current totalizer reading again.
You have the following individual setting options:
– Reset+Stop: the totalizer is set to 0 and held.
– Reset+Start: the totalizer is set to 0 and restarted 1,2
– Totalize: the totalizer is started 3
With this function you can select physical units or switch from one unit to another. In the
latter case the device converts the previous totalizer reading into the new unit.
Here you can set all values from 0 to +108. You can assign reaching
or exceeding this limit value as a signal to a digital output.
SITRANS F M TRANSMAG 2
Operating Instructions, 11/2009, A5E00102775-07