Figure 58: Manual Trigger Screen - FLIR CM-6206-H1-I User And Installation Manual

Hide thumbs Also See for CM-6206-H1-I:
Table of Contents

Advertisement

Configuration and Operation
Manual Trigger
The Manual Trigger screen is used to specify an alarm to be manually triggered. You can define action
to take when an alarm occurs from the
Manual Trigger
Select Off or On to activate this function. The default is Off.
Triggered Action
Specify one or both alarms to trigger:
Enable alarm output – Check this box and select the predefined type of alarm output (high or
low) to enable alarm relay when an alarm is triggered.
Send Message by FTP – The Administrator can select whether to send an alarm message by
FTP when an alarm is triggered.
Upload Image by FTP – Selecting this option enables you to assign an FTP site and configure
various parameters, as seen in Figure 50: Upload Image by FTP. When an alarm is triggered,
event images will be uploaded to the designated FTP site.
Note:
Images can be sent by FTP only when MJPEG is selected as the video stream from the
Format
screen.
Specify the FTP address to use from the drop-down menu. Select the number of frames for the
pre-trigger and post-trigger buffers from the drop-down menu of 1-20 frames.
70
System > Events Setup > IO

Figure 58: Manual Trigger Screen

CM-6206-H1-I User and Installation Guide
screen.
September 29, 2016
Video

Advertisement

Table of Contents
loading

Table of Contents