Configuration and Operation
Get IP address automatically
If you select Get IP address automatically, you can use the DNA utility, which is provided in the supplied
CD, to obtain the IP address from a DHCP server on the network. See
and Access the
Camera.
Note:
For future reference, record the camera's MAC address, which is found on the camera label.
Use fixed IP address
The camera's default setting is Use fixed IP address. Refer to
Access the Camera
for login with the default IP address. You may use DNA or enter the IP address in
your Internet browser's URL address bar.
To set up a new static IP address
1. Select the Use fixed IP address option.
2. Enter the following information:
IP address – The IP address is necessary for network identification.
Subnet mask – Used to determine if the destination is in the same subnet. The default
value is 255.255.255.0.
Default gateway – Used to forward frames to destinations in a different subnet. An invalid
gateway setting causes transmission to destinations in other subnets to fail.
Primary DNS – The primary domain name server that translates host names into IP
addresses.
Secondary DNS – A secondary domain name server that backs up the primary DNS.
To use PPPoE
1. Enter your PPPoE user name and password into the respective fields.
2. Click SAVE to confirm the settings.
Advanced
Enter the following advanced parameters in the Advanced section of the screen:
Web Server port – The default web server port is 80. Once the port is changed, the user must be
notified the change for the connection to be successful. For instance, when the Administrator
changes the HTTP port of the camera whose IP address is 192.168.0.100 from 80 to 8080, the
user must type in the web browser http://192.168.0.100:8080 instead of http://192.168.0.100.
RTSP port – The default setting of the RTSP port is 554. The range is from 1024 to 65535.
MJPEG over HTTP port – The default setting of MJPEG over HTTP port is 8008. The range is
from 1024 to 65535.
HTTPS port – The default setting of HTTPS port is 443. The range is from 1024 to 65535.
MTU – The MTU (Maximum Transmission Unit) is the greatest amount of data that can be
transferred in one physical frame on the network. For Ethernet, the MTU is 1500 bytes (default
setting). For PPPoE, the MTU is 1492. The range is from 700 to 1500 bytes.