Configuration and Operation
Sync with NTP Server
Network Time Protocol (NTP) is an alternate way to synchronize the camera's clock with an NTP server.
Enter the network time server host name or IP address to synchronize in the text box. Then select an
update interval (every hour, day or week) from the drop-down menu. For further information about NTP,
visit www.ntp.org.
Click SAVE when finished.

Security

Clicking the Security tab in the System sidebar opens a drop-down menu with the following screens:
User
User
The User screen is used for entering and managing user credentials and privileges, as well as
configuring authentication settings.
Admin Password
Change the administrator's password by entering the new password in both text boxes. The input
characters/numbers are displayed as dots for security purposes. After clicking SAVE, the web browser
asks the Administrator for the new password (maximum 14 digits).
Note:
The following characters are valid: A-Z, a-z, 0-9,!#$%&'-.@^_~.
40
HTTPS

Figure 27: User Screen

CM-6206-H1-I User and Installation Guide
IP Filter
IEEE 802.1X