10. Adjustments
Additionally to those ecom-EN2 functions described previously, various
adjustments can be made in the instrument.
From the main menu, select the sub-menu "Adjustments" and confirm
with <Enter>.
A selection of modifiable parameters,
adjustable according to the application,
is displayed.
Place the cursor on the desired line and
press <Enter> to call up or modify the
adjustment. The modifiable parameters
are:
Unit (adjustment with cursor keys):
- Calculation of gas concentrations in:
- ppm
- mg/m
3
- mg/kWh (undiluted) = mass concentration per power unit
- mg/MJ (undiluted)
- ppm (undiluted)
- mg/m
(undiluted)
3
Undiluted:
Conversion of the gas concentration on selected reference oxygen:
- mg/kWh and mg/MJ are always calculated on 0% O
- Conversion formula
O
reference
2
(for ppm und mg/m
- Input of O
2
ecom-EN2
= volume concentration (parts per million)
= mass concentration per volume unit
= mass concentration per power unit
= volume concentration (parts per million)
= mass concentration per volume unit
E
= E
ref
meas
- Input after pressing <Enter>):
3
reference value O
Adjustments
Unit
O
reference
2
Fuel type
Air pressure
Select
Clock set
Paper feed
Internal
21 - O
2 ref
*
21 - O
2 meas
2 ref
↵ ↵ ↵ ↵ ↵
↑↓
:
basis
2
Page 23