Pull out very carefully the lead flange in a straight manner (q.v. figure 10-7) , ensuring
that it does not tilt. Due to the created lower pressure, this might require some addi-
tional effort
The cylindrical clearance fit (H8f7 - DIN ISO 286) of the body as well as of the flange
components must not be tilted as this runs the risk of damaging the flame proof
gap pre-venting the transmission of ignition (DIN EN 60079-1:2008)!
Avoid skin or clothing contact at the cylindrical fit as it disposes of oleaginous fit-
ting compound (MOLYKOTE P-40) to protect the surface for frictional corrosion
and mechanical strain
-
Attention: Installed components (camera module, optic, temperature controller
etc.), which are fixed to the cable and supply flange have to be treated very care-
fully to avoid damages!
-
Attention: When removing the flange, do not damage or pollute the Gylon sealing
(style 3504 blue)!
-
After completion of the measure, the housing has to be closed again immediately.
Do not lock-in any foreign objects!
-
For closing the housing, please follow, in reversed order, the steps described for the
opening of the housing. Please observe the following warning instructions :
Attention!
Make sure to completely insert the flange in order to guarantee the ig-
nition protection type and the housing IP protection level
Attention!
Extensive tightening of the screw connection may damage the camera
Attention!
Beware not to damage the surface of bore hole and shaft (fit) at the flame
proof gap preventing the transmission of ignition.
Attention!
Please make sure not to damage housing sealings and to keep them
clean
Doc.-ID: 140721-PT08BAU-SS-Ex Installation Manual rev.03 (1st Supplement), page 19 of 52